After the Diaphragm mounting block have been installed, replace with the new Head (Casing)
block, reattaching the L-tube, and reinstall the 4 screws holding the Head (Casing) on. (Refer to
Fig.4- or )
Replacement of Safety Screw
SP Switch (For HP-60/HP-80/HP-100/HP-100LL/HP-120/HP-120LL/HP-150/HP-200 Series)
The body of the switch is set on the upper part of the Rod. If the Diaphragm is damaged or unit is
dropped, the unusual movement of the Rod will cause the upper part of the Rod to touch the L-
shaped lever, contacting the spring terminal, breaking the safety screw. This turns the power off,
stopping the pump automatically. This is a built in safety device to prevent any further damage to the
pump. To replace SP Screw:
REPLACEMENT SAFETY SCREW PART#
HP-60/HP-80/HP-100/HP-100LL/HP-120/HP-120LL/HP-150/HP-200 PASPSW0200
Fig. 6
First remove the pump plug from the electrical outlet.
All power must be disconnected or deenergized before servicing unit. If hazard is
WARNING:
ignored personal injury or property damage is possible.
Dispose of broken screw. Be sure all debris is removed (may be necessary to turn pump upside
down) from unit.
Fasten screw with plastic nut. The screw is designed so that the nut will turn freely when it is
properly fastened, stop tightening when this happens.
Reinstall the Upper housing
Reinstall the 4 screws holding the Frame cover on. (For HP-100/120, Refer to Fig.4- )
Reinstall the Sound absorber (except for HP-40, HP-100LL, HP-120LL).
Reinstall the Upper housing and tighten corner screws. (Refer to Fig.4- )
7
(Refer to Fig.6)
Nut
Spring
electrode
L-shaped lever
(Refer to Fig.4)
Beam
Safety screw