Celect SAS908XWHB-7-DF1 매뉴얼 - 페이지 10

{카테고리_이름} Celect SAS908XWHB-7-DF1에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Celect SAS908XWHB-7-DF1 10 페이지. Waterline master control controller

Celect SAS908XWHB-7-DF1 매뉴얼
2.
Permanent hold temperature setting
When thermostat is in program operation, press button ① over 3 seconds to enter the Permanent hold
mode . Press
change set temperature. The thermostat will permanent hold the room temperature at the
▲、 ▼
selected setting until you press
3.
Code match and Wireless Control:
1) According to the system requirements SAS2010DE connected to the power source (L, N 100 ~ 240 vac),
Check and energizing, Press the power button switch machine is normal or not electricity, light is lit.
Otherwise, Please replace the product, Then press the last step action to execute.
2) Open SAS908XWHB-7-DF1 backplane Load two batteries (AA) ,Closed the backplane, And check the
display and button functions, not normal replacement product, Press re-execute the previous step action.
(3) Energized normal SAS2010DE products in shutdown mode (indicator), press and hold the power button
until the indicator A long bright yellow release, this time SAS2010DE in the code state.
(4) The thermostat SAS908XWHB -7- DF1 in standby mode, long according to the thermostat R button
more than 3 seconds, Emission to code command.
(5) The success of the code receiving portion yellow flashing 01 blinks four times, Otherwise the code is
unsuccessful, Return reflector of the original code value.
Note: When in the process for the debug on/off, the interval of time should more than 4 sec,
otherwise the products have not time for react.
4.
Reset operation
If the display is abnormal, press the Reset button by using a fine probe such as a straightened paper
clip to gently push the Rest button. This will reset the thermostat.
5.
Battery note: 1)The battery power low battery warning sign "
2) Products when not in use for a long time, please take off, to prevent battery leakage
After reading this guide, if you have any question about the operation of your thermostat, please contact your
installer or service provider.
button to restart the program operation.
damage product

CUSTOMER ASSISTANCE

" flicker
10