HP- 150 / 200
STEP
STEP
4
4
Remove  2  U-lock  nuts  from  one  side  holding  the 
diaphragm mounting block to the rod.
●Use the nut driver to loosen (or tighten) the U-lock nut.
STEP
STEP
5
5
Remove  one  of  the  diaphragm  mounting  blocks 
from  the  actuating  rod  and  pull  out  the  other 
diaphragm  mounting  block  with  the  rod.  After 
that, separate the diaphragm mounting block and 
the rod. 
●When pulling out the rod, be sure not to catch the rod 
projection on the lever of the SP switch. 
●If  the  pump  stops  automatically,  the  safety  pin  must  be  broken  to  prevent  any 
further damage to the pump. Be sure all broken pieces are removed from the unit. 
(See Step 14)
STEP
STEP

REPLACING THE DIAPHRAGM

6
6
In  case  of  replacing  the  whole  diaphragm 
mounting block, move straight to 
Remove the diaphragm ring from the diaphragm, 
and  then,  detach  the  diaphragm  from  the 
diaphragm base.
STEP
STEP
7
7
Fit  a  new  diaphragm  and  diaphragm  ring  in  the 
diaphragm base.
 
●Be sure not to leave a gap between them.
REPLACING THE CHAMBER BLOCK
 
STEP 11
3