HP- 150 / 200
CAUTION
!
●Be sure to unplug the pump unit.
●When performing replacement work, the pump body may still be hot and you could
get burned. So please wait until the pump has cooled before handling.
●Be sure to remove the chamber block and the actuating rod before replacing the
electromagnet.
●It is better to let an experienced technician handle the soldering process.
Take precautions against getting burned.
STEP
STEP
REMOVAL OF ELECTROMAGNET
1
1
Cut the wire from the terminals on electromagnets
with nippers.
●It is recommended that you make a note of the wiring.
STEP
STEP
2
2
Loosen the screw, fixing SP switch and remove it .
(There are hexagonal nuts at SP switch side. Be
sure not to lose them as they fall inside the unit.)
STEP
STEP
3
3
Remove the hexagonal nuts by the nut driver.
(8mm wrench)
Loosen the screw holding the frame stay, and
remove it.
Pull out the electromagnet from the pump body.
REPLACING THE ELECTROMAGNET