AC POWER AND BATTERY CONNECTION
AC POWER CONNECTION
AC POWER CONNECTION
TRANSFORMER
1.
CONNECT THE TRANSFORMER TO TERMINALS 1 AND 2.
SEE WIRE RUN CHART.
TRANSFORMER WIRE RUNS
USE CAUTION WHEN WIRING
Distance from control Wire Size
THE TRANSFORMER TO THE
CONTROL TO GUARD AGAINST
Up to 50 feet
# 20
BLOWING THE TRANSFORMER
50 - 100 feet
# 18
FUSE (THE FUSE IS
100 - 200 feet
# 16
NON-REPLACEABLE).
2.
AFTER ALL WIRING CONNECTIONS ARE COMPLETE, PLUG
TRANSFORMER INTO A 110VAC UNSWITCHED OUTLET (24HR)
USE 1361X10 TRANSFORMER INTERFACE WHEN POWER
LINE CARRIER DEVICES ARE BEING USED.
"AC LOSS" DISPLAYED IF VOLTAGE FALLS BELOW 16.5VAC.
BATTERY
1.
PLACE THE 12-VOLT BACKUP BATTERY IN THE CABINET.
2.
AFTER ALL CONNECTIONS TO THE CONTROL ARE MADE AND
AC POWER HAS BEEN APPLIED, CONNECT THE RED AND
BLACK FLYING LEADS TO THE BATTERY.
CONNECT ONLY AFTER AC POWER HAS BEEN APPLIED.
IMPORTANT: THE PANEL WILL NOT POWER UP INITIALLY ON
BATTERY POWER ONLY. YOU MUST PLUG THE TRANSFORMER
IN FIRST, AND THEN CONNECT THE BATTERY.
SOUNDER CONNECTION
CONNECT SOUNDER TO BELL TERMINALS 3 (+) AND 4 (-).
SOUNDER ACTIVATES UPON ALARM EVENT.
ALARM OUTPUT: 10.5–13.8VDC, 2A MAX. (600mA MAX. FOR
UL USAGE, INCLUDING AUX POWER) STEADY FOR
BURGLARY/PANIC, TEMPORAL PULSE SOUNDING FOR FIRE.
UL: MUST BE A UL LISTED AUDIBLE SIGNAL APPLIANCE RATED
FOR 10.2-13.8 VDC AND BE MOUNTED INDOORS.
CAN USE ADEMCO No. 702 SIREN, OR 12V BELL.
A BATTERY MUST BE INSTALLED BECAUSE THE BATTERY
SUPPLIES THE CURRENT.
FOR SOUNDER SUPERVISION
UL: BELL SUPERVISION IS REQUIRED
FOR FIRE ALARM INSTALLTIONS.
EXTERNAL ALARM SOUNDER
IF BELL SUPERVISION IS
ENABLED (RED JUMPER ON
CONTROL BOARD IS CUT
TERM 4
AND
91 ENABLED)
2000 OHM
CONNECT A 2000 OHM
OBSERVE
EOL
POLARITY
RESISTOR ACROSS THE
TERM 3
RESISTOR
EXTERNAL SOUNDER AS
SHOWN BY THE DOTTED LINE.
DO NOT CONNECT THE RESISTOR AT THE ALARM OUTPUT TERMINALS THEMSELVES!
RF RECEIVERS & TRANSMITTERS
MODULE
1.
SET RECEIVER DEVICE ADDRESS TO "00" (SET SWITCHES TO
THE RIGHT, "OFF" POSITION).
2.
MOUNT THE RECEIVER INSIDE THE CABINET OR REMOTELY
WITHIN A NOMINAL RANGE OF 200 FEET FROM TRANSMITTERS,
IN HIGH, CENTRALLY LOCATED AREA.
3.
CONNECT THE RECEIVER'S WIRE HARNESS TO THE CONTROL'S
ECP TERMINALS. SEE RECEIVER'S INSTRUCTIONS FOR
ANTENNA MOUNTING, ETC.
4.
INSTALL TRANSMITTERS ACCORDING TO THEIR INSTRUCTIONS.
WIRELESS ZONE NUMBERS
VISTA-20P:
VISTA-15P:
40 TRANSMITTER ZONES: 9-48
26 TRANSMITTER ZONES: 9-34
16 BUTTON ZONES: 49-64
8 BUTTON ZONES: 49-56
ULC NOTE: THE RF SUPERVISION PERIOD FOR THE V20PCN AND
V15PCN IS THREE HOURS FOR FIRE ZONES (ZT 9 AND 16) AND
12 HOURS FOR ALL OTHER ZONE TYPES.
BATTERY FUSE
FOR REPLACEMENT,
RECHARGABLE
3A
USE SAME VALUE
CANADA: USE PSC04.
BATTERY
(e.g. ADEMCO No. 90-12)
SEE INSTALLATION INSTRUCTIONS.
(12V, 4AH)
FUSE NOTE
SEALED LEAD
MAY HAVE PTC IN
ACID TYPE
PLACE OF FUSE.
RED
BLACK
UL: PLC DEVICES AND 1361X10
ARE NOT UL LISTED FOR FIRE
OR BURGLARY FUNCTIONS
AND ARE INTENDED FOR
HOME AUTOMATION.
TO
1321
TERMINALS
(1321CN IN CANADA)
1 & 2
16.5VAC, 25VA, CLASS 2
PLUG-IN TRANSFORMER
ECP AUX POWER OUTPUT
10.5-13.8VDC 600mA MAX.
(500mA MAX. FOR UL INSTALLATIONS)
AC
AC BELL
GND
1
2
3
4219/4229
RF
EXPANDER
RECEIVER
MODULE
SENSORS
(USE 1K EOLR)
COMMUNICATION
DEVICE
CONTROLLED
DEVICES
4204
RELAY
BLACK
RED
GREEN
YELLOW
KEYPAD
KEYPADS AND ADDRESSABLE DEVICE CONNECTION
1.
CONNECT KEYPADS AND OTHER ADDRESSABLE DEVICES TO ECP TERMINALS 4-7.
(SEE "SETTING KEYPAD ADDRESS BOX TO SET KEYPAD ADDRESSES.)
TOUCHSCREEN NOTE: TOUCHSCREEN KEYPADS MAY REQUIRE AN EXTERNAL
POWER SUPPLY DUE TO AUX POWER LIMITATIONS.
2.
SET EACH MODULE'S ADDRESS ACCORDINGLY:
DEVICE
ADDRESS
DEVICE
ADDRESS
KEYPADS
16 - 23
5800TM
28 (PART. 1 ONLY)
4219, 4229
07 - 11
COMM DEVICE
03
4204
12 - 15
4286
04
RF RECEIVER
00
TOUCH SCREENS
V15P: 1, 2
V20P: 1, 2, 5, 6
TRIGGER CONNECTOR
USED FOR 1361X10
+
5
TRANSFORMER
CONNECTIONS AND FOR
ON-BOARD TRIGGERS.
AUX PWR
PROGRAM RELAY
OUT 17 = 100mA MAX
OUTPUT
AS ZONE TYPE 54
OUT 18 = 20mA MAX
TERMINALS
(FIRE ZONE RESET)
1 2 3 4
5 6
7 8
4
OPTIONAL
OR
CONTACT OPENS MOMENTARILY
1361X10
UPON FIRE ALARM RESET
TO OUTPUT 17
PROGRAM OUTPUT 17 FOR
"OUT NORM LOW" = YES IN
79 MENU MODE AND AS ZONE
BLUE (DATA)
TYPE 54 IN
80 MENU MODE
MAX. CURRENT = 100 mA
PURPLE (COM)
BLACK (SYNC)
(USE SA4120XM-1 CABLE)
(+)
TO ZONE 2 8 TERM.
RED JUMPER
CUT FOR BELL SUPERVISION.
( )
ALSO, CONNECT 2000 OHM
RESISTOR DIRECTLY ACROSS
SOUNDER AND ENABLE FIELD
91.
ECP DEVICES
HARDWIRE ZONES
AUX
IN
OUT
Z1+
Z1
GND
Z2
Z3
GND
Z4
Z5
GND Z6
Z7
4
5
6
7
8
9
10
11
12
13
14
15
16
17
2000
2000
2000
2000
2000
2000
OHMS
OHMS
OHMS
OHMS
OHMS
OHMS
EOLR
EOLR
EOLR
EOLR
EOLR
EOLR
2-WIRE SMOKE
DETECTORS
(16 MAX) OR
STANDARD
2K EOLR
HARDWIRE ZONE CONNECTION
1.
OPEN CIRCUIT DEVICES CONNECT IN PARALLEL ACROSS
THE LOOP; FOR EOLR ZONES, CONNECT THE EOLR
ACROSS THE LOOP WIRES AT THE LAST DEVICE.
2.
CLOSED CIRCUIT DEVICES CONNECT IN SERIES IN THE
HIGH (+) SIDE OF THE LOOP; FOR EOLR ZONES, CONNECT
THE EOLR IN SERIES FOLLOWING THE LAST DEVICE.
EOLR NOTE:
IF THE EOLR IS NOT AT THE END OF THE LOOP, THE
ZONE IS NOT PROPERLY SUPERVISED AND THE SYSTEM
MAY NOT RESPOND TO AN "OPEN" ON THE ZONE.
UL NOTE:
FOR UL COMMERCIAL BURGLARY ALARM INSTALLATIONS,
USE EOLR ZONES.
DOUBLE-BALANCED ZONE
ZONE DOUBLING
VISAT-20P ONLY
VISTA-20P ONLY
PROVIDES ZONE TAMPER
PROVIDES TWO HARDWIRED
PROTECTION AND SHOULD BE
N.C. ZONES FOR EACH
USED AS BURGLARY ZONES ONLY.
STANDARD HW ZONE
A SHORT ACROSS THE EOL
(BUT DOES NOT INCREASE
CAUSES A TAMPER CONDITION.
TOTAL NUMBER OF ZONES
SUPPORTED. A SHORT ACROSS
THE EOL ON EITHER ZONE
CAUSES A TAMPER CONDITION.
12
13
14
ZONE NUMBERS USED FOR
DOUBLING CANNOT BE USED
FOR ANYTHING ELSE.
2k
2k
10
ZONE 2
2k
2k
ZONE 10
2k
2k
ZONE 3
ZONE 4
DO NOT USE DOUBLE-BALANCED ZONES
OR ZONE DOUBLING FOR FIRE ZONES.
4-WIRE SMOKE DETECTOR CONNECTIONS
RELAY
BLK
+
RED
EOL
POWER
N.O.
SUPERVISION
N.C.
RELAY MODULE
A77-716B.
USE N.O.
CONTACT,
VIOLET
WHICH CLOSES
+
WHEN POWER
IS APPLIED.
4-WIRE SMOKE
2000
OR COMBUSTION
DETECTOR
OHMS
EOLR
HEAT
DETECTOR
HANDSET
INCOMING
GND
Z8
TIP
RING
TIP
RING
GND
18
19
20
21
22
23
24
25
EARTH
GROUND
EARTH GROUND CONNECTION
2000
2000
THIS CONTROL DOES NOT NORMALLY NEED AN EARTH GROUND. IF
OHMS
OHMS
DESIRED FOR ADDITIONAL PROTECTION, CONNECT TERMINAL 25 TO A
EOLR
EOLR
GOOD EARTH GROUND. EXAMPLES OF GOOD EARTH GROUNDS:
VISTA-20P ONLY
METAL COLD WATER PIPE: USE A NON-CORROSIVE METAL STRAP
(COPPER IS RECOMMENDED) FIRMLY SECURED TO THE PIPE TO WHICH
THE GROUND LEAD IS ELECTRICALLY CONNECTED AND SECURED.
AC POWER OUTLET GROUND: AVAILABLE FROM 3-PRONG, 120VAC
POWER OUTLETS ONLY. TO TEST THE INTEGRITY OF THE GROUND
TERMINAL, USE A 3-WIRE CIRCUIT TESTER WITH NEON LAMP
INDICATORS, SUCH AS THE UL LISTED IDEAL MODEL 61-035, OR
EQUIVALENT, AVAILABLE AT MOST ELECTRICAL SUPPLY STORES.
RING (GRAY)
PREMISES
TIP (BROWN)
PHONES
RING (RED)
1
2
3
4
RJ31X
5
TIP GREEN)
8
7
6
PHONE CONNECTION
1.
CONNECT PHONE LINE DIRECT
CONNECT CABLE WIRES TO
TERMINALS 21-24 AS SHOWN.
WIRE COLORS REPRESENT THE
COLORS OF THE CABLE TO THE
RJ31X JACK.
2.
CONNECT INCOMING PHONE
LINE AND HANDSET WIRING TO
1.
ZONE
THE MAIN TERMINAL BLOCK
PAIRS
(VIA AN RJ31X JACK; CA38A IN
11
CANADA) AS SHOWN.
2 / 10
3 / 11
2.
4 / 12
5 / 13
6 / 14
3k
7 / 15
8 / 16
3.
6.2k
KEYSWITCH WIRING CONNECTIONS
1 2 3 4
5 6
7 8
TRIGGER CONNECTOR
UL: SEE INSTALLATION INSTRUCTIONS
FOR USAGE AND LIMITATIONS.
4146 KEYSWITCH
STANDARD
(ARMED)
KEYPAD
RED
CABLE
YELLOW
(READY)
GREEN
WHITE
820
820
ohms
ohms
BLACK
RED
TAMPER
SWITCH (N. C.)
BROWN
BROWN
11
TYPICAL ZONE
LOCK
ON CONTROL
SWITCH (N. O.)
BOARD
BLUE
BLUE
10
2K OHM EOLR
INCOMING
TELCO
SETTING KEYPAD ADDRESS
HOLD
DOWN
THREE
SECONDS
1
2
3
ARMED
OFF
AWAY
STAY
4
5
6
READY
MAX
TEST
BYPASS
8
9
7
INSTANT
CODE
CHIME
#
0
READY
POWER UP THE KEYPAD. WITHIN 60 SECONDS OF
POWER-UP, PRESS AND HOLD DOWN THE [1] & [3] KEYS
AT THE SAME TIME FOR 3 SECONDS.
ENTER THE PROPER "TENS" DIGIT OF THE KEYPAD'S
ADDRESS, THEN ENTER THE PROPER "ONES" DIGIT
OF THE KEYPAD'S ADDRESS.
NOTE: FIRST KEYPAD IS ADDRESS 16
PRESS [ ] TO SAVE THE DISPLAYED ADDRESS AND
EXIT ADDRESS MODE.
V15P_V20P_quick-guide_CL