36.
Connect a voltage meter to potentiometer terminals so positive lead is connected
to S and negative lead is connected to CW.
37.
Rotate entire potentiometer/mounting bracket assembly so output is between 0.04
and 0.1 VDC.
38.
Tighten socket head cap screw to lock sensor bracket in place
39.
Replace sensor cover, making sure o-ring seats properly.
40.
Replace the 4 socket head cap screws that attach the sensor cover to the housing.