Troubleshooting The Bulb Eater
Carefully following the instructions and guidelines in this manual is the best way to keep your Bulb Eater
working properly. However, should you encounter problems, this guide will help you resolve issues that
occasionally arise during normal use of the Bulb Eater
addressed here or if your problem persists after following these suggested procedures, do not hesitate to
contact us at 800.909.9709 or [email protected] for further assistance.

General Use

Bulb Eater
®
runs with low suction or is overheating
Low suction and overheating can be an indication that your 1st or 2nd Stage fi lters need to be changed. In
ideal conditions, crushing clean bulbs, 1st Stage fi lters should be changed twice a drum and the 2nd stage
fi lters, every 10 drums. However, dirty bulbs and various environmental conditions can cause fi lters to fi ll
more quickly.
1.
Replace the 1st Stage fi lter (instructions can be found in the Maintenance & Troubleshooting section)
2.
If the problem persists, replace the 2nd Stage fi lter.
Lamps break regularly in the entry tube
1.
Do not force lamps down the entry tube. The Bulb Eater
the lamps into the machine.
2.
Ensure that you always crush lamps using appropriately sized entry tubes to minimize external breakage.
Entry tubes are available at www.aircycle.com for a wide variety of lamp sizes.
3.
If you are crushing lamps with signifi cantly blackened ends, feed the lamps blackened end fi rst. These
portions of glass are slightly weaker and more prone to breakage outside the machine.
4.
Crushing lamps that have previously been taped together can result in a buildup of adhesive in the Bulb
®
Eater
entry tubes and cause breakage. Remove the entry tube from the machine and clean the inside of
the tube with a rag soaked in an appropriate solvent like paint thinner.

Control Panel Lights

"Power" light does not illuminate when machine is plugged in and is operating
If your Bulb Eater
®
functions normally when plugged in but the power light does not illuminate, you likely
have a faulty light. The Bulb Eater
®
Bulb Eater
with no changes.
"Lid Open" light is on when the Bulb Eater
The lid open sensor is a safety shut off to prevent the operation of the machine if it is not installed on a drum.
If the light is lit when the lid is installed properly:
If your machine has a white sensor block (found on the underside of the Bulb Eater
instructions found on page 8.
If your machine has a black sensor block – Remove the set screw retaining the sensor and with a small
screwdriver set, slide the sensor out so it is fl ush with the end of the block. Then reinstall the set screw to
lightly hold the sensor in place.
800.909.9709
www.aircycle.com
Still having problems? Contact Air Cycle at 800.909.9709
®