2.1 Definitions

ACC_MH – AC Current Measured High
ACC_ML – AC Current Measured Low
ACV_MH – AC Voltage Measured High
ACV_ML – AC Voltage Measured Low
ACC_RH – AC Current Reference High
ACC_RL – AC Current Reference Low
ACV_RH – AC Voltage Reference High
ACV_RL – AC Voltage Reference Low
LOW_CUR_WEIGHTED_AVG – 5
LOW_VOL_WEIGHTED_AVG – 2
ACC_S – AC Current Slope
ACV_S – AC Voltage Slope
ACC_O – AC Current Offset
ACV_O – AC Voltage Offset

2.2 AC Current Slope Calculation

slope = (ACC_MH – ACC_ML) / (ACC_RH – ACC_RL)
If slope < 0.78 Then
ACC_S = -126
Else If slope > 1.4 Then
ACC_S = 126
Else
ACC_S = (1 - (1 / slope) * 440
End If

2.3 AC Voltage Slope Calculation

slope = (ACV_MH – ACV_ML) / (ACV_RH – ACV_HL)
If slope < 0.929 Then
ACV_S = -126
Else If slope > 1.083 Then
ACV_S = 126
Else
ACV_S = (1 - (1 / slope)) * 1651
End If