Safety Guidelines

Adhere to the following guidelines to ensure the safety of all personnel when installing any GAI-Tronics
equipment:
Do not install wiring during a lightning storm.
Electrostatic Discharge (ESD) Protection: The VoIP telephone may have an earth ground terminal
provision. If so, it must be connected to ground in accordance with all local safety regulations and
the National Electrical Code (NEC). Grounding must be ensured for safe and stable communications.
Do not use long and coiled ground wires. Trim ground wires to the required length. Use a star
configuration whenever possible. Please note that proper grounding does not eliminate the need for
lightning protection for the telephone or the telephone system. A Cat5 data line lightning surge
protector is recommended for telephones subject to any electrostatic discharge (e.g. lightning).
Do not install jacks in wet locations unless the jack is specifically designed for wet locations.

Station Placement

Volume settings and station placement must be taken into consideration to prevent feedback problems in
the system. To reduce unpleasant feedback problems:
point the telephone away from other telephones located nearby
reduce the volume level
Avoid feedback problems by installing each Clean Phone

Model 295-702F

The mounting and wiring instructions are as follows:
1. Remove the front panel from the back bracket.
2. Mark the wall using the cut-out dimensions as a guide (see Figure 6).
3. Make the required cuts to create the opening for the back box.
4. If using Power-over-Ethernet, with no optional inputs or outputs:
place the bushing around the Ethernet cable so that it is located
approximately 5 inches from the end of the cable. Snap the
bushing closed and insert into the double D hole in the bottom of
the back bracket. See Figure 4 and Figure 7).
5. If using local power or optional inputs or outputs: route the
cables through the D hole in the bottom of the back bracket (see
Figure 7).
6. Place the back bracket in the wall. Locate the mounting holes
(see Figure 7).
7. Drill holes in the lower right and upper left corners and secure the
bracket with screws.
8. Drill the remaining holes and secure the bracket with the remaining screws.
9. Plug in the Ethernet cable and connect all other optional cables (see the Field Wiring section).
10. Perform the initial programming of the telephone (see the Programming section).
11. Take the front panel of the VoIP Clean Phone
12. Press the panel in firmly and then push downward to seat the panel in the slots.
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-470G.docx
05/19
®
VoIP telephone in a separate room and wall.
®
and align it with four slots in the back bracket.
Pub. 42004-470G
Page 5 of 15
Figure 4. Bushing