{카테고리_이름} GAI-Tronics 298-103에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. GAI-Tronics 298-103 20 페이지. Externally powered emergency phones
S.M.A.R.T. E
P
XTERNALLY
Models 293-103, 293-103AL, and 294-103AL
The mounting and wiring instructions for Models 293-103, 293-103AL and 294-103AL are as follows:
1. Remove the front panel of the telephone by
removing the four tamper-resistant screws.
2. Remove the front panel of the enclosure.
Carefully place the front panel assembly in a safe
location while installing the back box.
3. Position the enclosure on the mounting surface.
The enclosure provides four 0.28-inch mounting
holes. Secure it with the four ¼-inch diameter
bolts of the appropriate length for the mounting
surface.
4. For Model 293-103 only, create an access hole
using a Greenlee-type punch that is equivalent in
size to the conduit diameter. Bottom entry is
strongly recommended. Insert a conduit fitting
in the access hole. Refer to conduit installation
details on page 4.
N
: Use silicone sealant or equivalent around and inside all conduit entries.
OTE
Figure 2. Model 294-103AL
N
: When using the GAI-Tronics Model 231-001 Pole Mounting Kit, follow the mounting
OTE
instructions provided in the kit.
d:\standard ioms - current release\42004 instr. manuals\42004-377c.doc
08/06
ADA-C
OWERED
OMPLIANT
E
P
MERGENCY
HONES
Figure 1. Model 293-103 and Model 293-103AL
5. Pull the telephone line and power supply cord
through the conduit. Connect the power supply 4-
pin connector to the P17 header jack on the
PCBA.
6. Connect the telephone line directly to TB1 (Tip
and Ring terminals) or install a modular jack in
the back of the enclosure and connect the pre-
installed modular plug to the jack.
7. Using the Setup section of this manual:
•
Make hardware configuration changes.
•
Adjust the audio levels if necessary.
•
Perform the initial programming.
8. Verify the phone is operating properly by calling
to and from another phone.
9. Complete the installation by attaching the front
panel assembly to the rear enclosure using the
four tamper-resistant screws.
PUB. 42004-377C