AirCycler g2-k 설치 테스트 매뉴얼 - 페이지 2
{카테고리_이름} AirCycler g2-k에 대한 설치 테스트 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. AirCycler g2-k 2 페이지.
AirCycler g2-k에 대해서도 마찬가지입니다: 설치 및 사용 설명서 (11 페이지), 교육 매뉴얼 (20 페이지), 설치 테스트 매뉴얼 (2 페이지)
HINTS & TIPS
•
Make sure the FanConnect switch is in the OFF position when the AirCycler® g2 controller is rst
powered on.
•
Setup is easier to start without the battery installed. The battery is only used for the real time clock.
If you are not using the operating hours options, the battery is not needed.
TROUBLESHOOTING
No power?
Check common wire connection. "C" must be connected to "C" on the furnace.
EXH icon is ashing
If the EXH icon is ashing it is indicating that the FanConnect switch has been on for more than four
hours or has lost connection with the g2 controller.
My furnace fan runs constantly
Make sure the thermostat FAN switch is set to AUTO and not ON.
Fan does not shut o when AirCycler
is on) Check wiring - G wire from thermostat should not be wired to Gt on AirCycler. Gf on AirCycler
should be connected to G on furnace.
FAQ
Will the AirCycler controller lose the settings if the power fails?
No, all settings are saved in non-volatile memory. No battery is needed.
The AirCycler® g2 has a small lithium battery to keep the clock running if you are not ventilating 24hrs
a day and are using that feature. It will maintain the time without power for at least 14 days.
Can I run multiple FanConnect switches o of one AirCycler® g2 controller?
No. For additional bathrooms use the SmartExhaust bath fan/light switch as an independent controller.
®