Automatic Technology Australia EasyRoller GDO-4 설치 지침 및 사용 설명서 - 페이지 4

{카테고리_이름} Automatic Technology Australia EasyRoller GDO-4에 대한 설치 지침 및 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Automatic Technology Australia EasyRoller GDO-4 16 페이지.

Featurgs
cont...
OPEN AND CLOSE
DRIVE BUTTONS
Another feature developed
by
Automatic Technology Australia
in
aiding
in
the
installation of the
Opener are
the Open and
Close
Drive Buttons.
These
buttons are
used
to
help set
the open
and close
limit positions.
The
quicker
setting
time and a
more precise
limit position
can
be achieved
using
this
system.
AUTO CLOSE MODE
The
Opener can be
programmed
to
automatically close
approximately
thirty seconds after
the
door
has opened.
A
Photo
Electric
Beam
must
be installed
if
this
mode is selected.
AUTO RUN TIME
lf
the
Motor
is
left
running
in the
Opener for
any
reason the Auto
Run Time will
turn the
motor off
after
thirty
seconds.
PHOTO ELECTRIC BEAM
The Opener
has
an
input for
a
Photo
Electric Beam
to
be
connected
for extra
safety
protection.
15.
AUTO
CLOSE (J2)
lnput
is
used for selecting
the
auto
close
mode.
lf auto close
is
selected
the
door will
automatically close
approximately 30
seconds
after
opening.
To
select,
remove
shunt
from
P.E.
input connector
and
place
on
auto close
connector
pins. NOTE:
a
P.E.
Beam must
be
used
when
auto
close
is selected.
16.
SEGURALIGHT
lnput
is
used
for connecting
a
Securalight
(optional extra) Monitor. A
Securalight is
a monitor
unit
which
is mounted inside your
home
and
is connected to the
Opener
by
wire
cable.
The
monitor indicates
the
status of
the door, for example if the
door
is moving, is opened
or
closed, etc. An audible beeper
sounds whenever the
door
is
moved by
the
Opener. The
door
can
also
be controlled
from the monitor
unit.
17.
O/S/C
lnput
is for connecting
the Wall Switch.
18.
WALL SWITCH is
usuatty
mounted inside
the
garage.
Pressing
the
Open
/
Close
button on the
wall
switch will
open,
close or stop
the
door.
Pressing
the
Light button will
turn the light
in
the Opener
on
or
off. lf
the
light comes
on
and
you do not press to
turn
off,
the
light will
turn
off automatically
after
about
3
minutes.
19,
ENGAGVDISENGAGE
HANDLE when
pulled down
and
released
will
select
manual mode
when there
is
a
power failure. Pulling down and
releasing again
will
select
automatic mode.
20.
STANDBY BATTERY SHUNT
must be removed
when
using
Battery Back Up Option.
1.
2.
3.
4.
5.
6.
v
Operating Gontrols
O/S/C
Button
(yellow)
is
used
during
installation to
test
the
open,
close and
stop
commands to
the
Opener.
Pressing
this
button
will
open,
close
or
stop the door.
CODE
SET
Bufton
(blue)
is
used for
storing
or erasing your
selected security
code from
your
transmitter(s)
into the
Openers memory
device.
OPEN
DRIVE
Button
(green)
is
used
during
installation to
help set the
open
limit stop
position.
Pressing
and
holding
this
button
will
move
the door
in the open direction.
Movement stops when the
button
is
released or when the
open
limit switch is activated.
NOTE:
The
open obstruction
detection
is inoperable
whenever
the Open
Drive
button
is
used
to
move door.
OPEN LIMIT Led
(green)
illuminates whenever the open
limit switch is activated.
The
led
is
very
helpful
during
installation.
CLOSE
DRIVE
Button (red)is
used
during
installation
to
help
set the
close
limit
stop
position.
Pressing
and
holding this
button
will
move
the door
in the
close direction. Movement
stops when
the
button
is
released
of
when
the
close
timit switch is activated.
NOTE:
The
close safety
obstruction
detection
is
inoperable whenever the
Close
Drive button
is
used to
move door.
CLOSE LIMIT
Led
(red)
illuminates whenever the close
limit
switch
is activated.
The
led
is
very
helpful
during
installation.
OPEN
FORCE
ADJUSTMENT
Shaft
(green) is for adjusting
the
open obstruction force.
Turning
the shaft
in a clockwise
direction
increases the force
that is
required
to
restrict the
door
before it stops when
opening. Turning anticlockwise
will
decrease the force
that
is
required
to
stop
the
door.
8.
CLOSE
FORCE
ADJUSTMENT
Shaft
(red)
is
for adjusting the
close
safety
obstruction force. Turning the
shaft
in a clockwise direction
increases
the
force
that
is
required
to
restrict
the door
before
it
reverses when
closing. Turning anticlockwise
will
decrease
the
force
that
is
required
to
reverse the
door.
NOTE:
The
open
and
close
safety obstruction
forces
need
to
be
tested at
regular intervals
(once
a
month) and the
necessary
adjustments
made.
9.
OPEN LIMIT CAM
(green)
is
used
to
set
the open
limit
stop
position.
Check
lnstallation
section
on
how
to
adjust.
10.
OPEN
LIMIT
ADJUSTMENT
SCREW
(green)
is
used to fine
adjust
the open
limit stop
position.
Check
lnstallation
section
on
how
to
adjust.
11.
CLOSE LIMIT CAM
(red)
is
used
to
set the
close
limit stop
position.
Check
lnstallation
section
on
how
to
adjust.
12.
CLOSE LIMIT ADJUSTMENT
SCREW
(red)
is
used to fine
adjust
the close
limit stop
position.
Check
lnstallation
section
on
how
to
adjust.
13.
P.E.
lnput
is for connection
of
Photo
Electric
Beams (optional
extra) for extra safety
obstruction
protection.
The
P.E.
shunl
must
be
removed when
a PE.
is connected.
14.
P.E.
SHUNT
must not
be
removed
othenarise
the
Opener
wilt not
function
correctly.
Remove only
when a
P.E.
is to
be connected
7.