Installation Guide
iCLASS™ Reader Models R10, R30, R40, RW300, RW400
PARTS INCLUDED
•
1 - iCLASS Reader
•
1 - Installation Manual
•
2 - 3.5mm x .6 pitch x 12mm Phillips machine screws
•
3 - #6-32 x .375" Phillips self-tapping machine screws
•
2 - #6 x 1.5" Phillips sheet metal screws
•
1 - #6 x .375" Spanner security screw, anti-tamper
Recommended:
•
Up to 9 wire splices
•
Cable, 5-9 conductor (Wieg. or RS232), 22awg shielded
•
Linear DC Power supply
•
Metal or plastic junction box
•
Magnetic switch - Ademco 945T, Sentrol 1038T, GRI 100T
or 110T or Aleph DC-2531
•
Security Tool (for anti-tamper screw) HID 04-0001-03
INSTALLATION
1- Disassemble
1- Remove Screw
2- Install Tamper Switch
An internal magnet provides tamper indication when used with a magnetic reed switch connected to an external alarm
system. (Except R10). Locate Switch behind the left side of the mounting plate, centered between the mounting holes.
An ASSA ABLOY Group company
_____________________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
Web page - www.hidcorp.com e-mail – [email protected] iClass ™ Reader Installation Manual 6090-900 Rev 8
2 - Lift Bottom of Bezel
3 - Slide Bezel up and remove
Electrical Back Box
SPECIFICATIONS
•
R10 (Mullion).................10 - 16VDC / 65-225mA
•
R30/RW300 (Euro).........10 - 16VDC / 80-260mA
•
R40/RW400 (US)............10 - 16VDC / 80-260mA
•
Cable distance to Host.....Wiegand - 500 feet (152m) max
•
Temperature..................-35° C to 65°C
•
Open collector output.......sink - 40mA, source - 1mA
Standards:
•
Read/Write* capability in ISO 15693-2 mode with HID
iCLASS credentials
•
Read/Write* capability in ISO 14443-B2 mode with HID
iCLASS 16Ks and other 3
•
CSN read capability for ISO 14443-A1 with HID Mifare
rd
and other 3
party Mifare credentials
4 - Lift top of Reader Assembly
5 - Slide down and remove
Wall Surface
RS-232 - 50 ft (15m)
rd
party credentials
* R10, R30, R40 are read-only
ASSA ABLOY
Page 1 of
3