HID iCLASS RK40 설치 매뉴얼
{카테고리_이름} HID iCLASS RK40에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. HID iCLASS RK40 2 페이지.
HID iCLASS RK40에 대해서도 마찬가지입니다: 설치 매뉴얼 (13 페이지), 설치 (2 페이지)
Installation Guide
iCLASS Reader Models RK40 & RWK400
PARTS INCLUDED
•
1 - iCLASS Keypad Reader
•
1 - Installation Manual
•
2 - 3.5mm x .6 pitch x 12mm Phillips machine screws
•
3 - #6-32 x .375" Phillips self-tapping machine screws
•
2 - #6 x 1.5" Phillips sheet metal screws
•
1 - #6-32 x .375" Spanner security screw
Recommended:
•
Up to 10 wire splices *
•
Cable, 9 conductor, 22AWG, shielded (Wiegand)
•
Cable , 6 conductor, 22AWG, shielded (Serial)
•
Linear DC Power Supply
•
Metal or plastic junction box
•
Security Tool (for security screw) HID 04-0001-03
•
Magnetic Tamper switch - Ademco 945T, Sentrol
1038T, GRI 100T or 110T or Aleph DC-2531
* RK40 available with 18" wire pigtail or 10-pos. removable
screw terminal connector. RWK400 includes 8-pos. and 10-
pos. removable screw terminal connectors.
INSTALLATION
1- Disassemble
2- Install Tamper Switch
An internal magnet provides tamper indication when used with a magnetic reed switch connected to an external alarm
system. Locate Switch behind the left side of the mounting plate, centered between the mounting holes.
Electrical Back Box
An ASSA ABLOY Group company
_____________________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
Web page - www.hidcorp.com e-mail – [email protected] iClass Keypad Reader Install Manual 6094-901 Rev A
SPECIFICATIONS
•
Voltage Range:
•
Current:
•
Cable distance to Host:
•
Op. Temperature:
•
Open collector output:
Standards:
•
Read/Write* capability in ISO 1SO 15693-2 mode with HID
iCLASS credentials.
•
Read/Write* capability in ISO 1SO 14443-B mode with HID
iCLASS 16KS.
•
Read capability of CSN/UID in ISO 1SO 14443-A1 mode
with HID Mifare and other 3
* RK40 is a read only, while RWK400 is a read/write unit.
A.
Remove the screw at the bottom of the unit.
B.
Lift the mounting plate out at the bottom side
C. Slide mounting plate down
Wall Surface
12VDC (10 - 16VDC).
100mA avg / 220mA peak.
500ft (152m) max – Wiegand.
50ft (15m) max – RS-232.
4000ft (1216m) max – RS-485.
-31°F - +149°F (-35°C – +65°C)
Sink – 40mA, source – 1mA.
rd
party Mifare credentials.
ASSA ABLOY
Page 1 of 2