AIRCYCLER® G2-K INTRODUCTION
The AirCycler® g2-k Whole House Mechanical Ventilation System includes the AirCycler® g2 Furnace Fan Timer,
FanConnect™ Bath/Fan Light Switch with remote fan control, and a motorized fresh air damper.
The AirCycler® g2 is a furnace fan timer and ventilation controller with outputs for operating a motorized fresh air
damper and the FanConnect™ exhaust fan switch*. This product provides whole house supply ventilation through cen-
tral furnace fan integration as well as whole house exhaust ventilation.
How does it work?
The AirCycler® g2-k System is integrated with the home's HVAC system. When the home's furnace fan is turned on
by the thermostat to provide heating or cooling, the AirCycler® g2 controller opens the motorized damper to let in
a measured amount of fresh air. The fresh air is filtered by the return plenum filter and is then distributed uniformly
throughout the home through the existing ductwork. Once the ventilation requirements are met, the damper is closed
to prevent over-ventilation.
By running the ventilation system at the same time as the home's regular heating and cooling cycles, the AirCycler®
g2-k System saves on additional utility costs.
Should regular heating and cooling cycles not run long enough to meet the desired or required ventilation, the
AirCycler® g2 can turn on the smaller and more economical bathroom exhaust fan (or other exhaust fan) through the
optional FanConnect™ Switch. With no need to run the large central fan to provide additional ventilation, homeowner
complaints of cold air or noisy operation are eliminated and efficiency is drastically improved.