INTRODUCTION
The SmartExhaust™ is designed to replace bathroom fan and light switches and provide both functions with one easy
operation. By using a microprocessor to monitor and control operation, the SmartExhaust™ delivers a precise amount of
ventilation.
BENEFITS
•
Earn LEED and ENERGY STAR points for enhanced exhaust ventilation*
•
Make standard bath fans ASHRAE 62.2 compliant*
•
Replaces both fan and light switches for one easy operation
•
Microprocessor technology provides precise ventilation times
•
Programmable DELAY and VENTILATION settings
•
Excess manual and/or delay operation is subtracted from the next hour's programmed ventilation time
•
Works with most incandescent, CFL, fluorescent and LED lights
•
Optional light and fan time out after 60 minutes (Rocker version only)
*When used with ASHRAE 62.2 compliant fans
SAFETY CONSIDERATIONS
Read and follow manufacturer's instructions carefully. Follow all local electrical codes during installation. All wiring
must conform to local and national electrical codes. Improper wiring or installation may result in personal injury or
product and property damage.
INSTALLATION
1. Do not connect this device to aluminum wire.
2. Use with copper or copper clad wire only.
3. TURN POWER OFF at circuit breaker or fuse panel.
4. Remove cover plate and existing switch from wall box if there is one already installed.
5. Connect the wires in the wall box using the supplied wire nuts.
Wires must have ¾ inch of bare copper exposed. Twist wires together tightly with supplied wire
nuts. Make sure no bare copper is exposed. Secure connections with electrical tape. If a light is not connected, be
sure to attach a wire nut to unused blue wire and secure with electrical tape.
6. Mount SmartExhaust™ switch in to wall box with supplied mounting screws.
7. Set desired DELAY time by turning dial to desired minutes.
8. Set desired VENTILATION time by turning dial to desired minutes per hour.
9. Record settings on face plate with an indelable marker and snap rocker assembly onto face plate.
10. Turn on power at circuit breaker or fuse box.
Note: To fully comply with ASHRAE 62.2 - Attach clear ASHRAE sticker to face of switch plate.