HID Aero X300 설치 매뉴얼

{카테고리_이름} HID Aero X300에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. HID Aero X300 7 페이지. Output control module

Output Control Module
Supplied parts
◾ HID Aero X300 Ouput Control Module (1)
◾ Installation guide (1)
◾ Mounting screws (4) 0.138" × 1" (3.5 mm × 25 mm)
Recommended parts
(not supplied)
◾ Certified DC power supply
◾ Drill with various bits for mounting hardware
◾ For DIN rail mounting: Brackets (2) - Phoenix Contact,
USA 10 Series Rail Adapter, part number 1201578.
Screws (4) - Self tapping, countersunk,
3.0 mm × 10 mm (or 3.0 mm × 8 mm)
X300 Overview
The X300 has 12 relays, five inputs and one RS-485 port for IO module connection.
Status LEDs
See page 6
RELAYS 1-12
See step 4.
"
4.53
(115 mm)
INPUTS 1-2
See step 3.
JUMPERS
See step 2.
INSTALLATION GUIDE
CABLE REQUIREMENTS (NOT SUPPLIED)
IO Module
Alarm Inputs
Relay Outputs As required for the load
Power
POWER, TAMPER, AC FAIL, BATT FAIL
See step 6.
"
5.51
(140 mm)
PLT-04236, Rev. A.3
One twisted pair, shielded, 24 AWG, 120
impedance, 4,000 ft (1,200 m) maximum
One twisted pair, 30 maximum
2-conductor shielded
18 to 16 AWG, 500 ft (150 m)
Status LEDs
See page 6
RELAYS 1-12
See step 4.
INPUTS 1-2
See step 3.
DIP SWITCH
See step 5.
IO MODULE PORT
See step 2.