Air conditioner cycles on and off too much or does not cool
The Mode is set to Power Saver (on some models). Use Power Saver only when you are
away from home or asleep, since the fan does not circulate the room air continuously. Use
Low, High or Turbo for your best comfort.
The air conditioner is not properly sized for your room. Check the cooling capabilities of
your room air conditioner. Room air conditioners are not designed to cool multiple rooms.
The filter is dirty or obstructed by debris. Clean the filter.
The inside evaporator and outside condenser coils are dirty or obstructed by debris.
See "Annual maintenance."
There is excessive heat or moisture (open container cooking, showers, etc.) in the
room. Use a fan to exhaust heat or moisture from the room. Try not to use heat-producing
appliances during the hottest part of the day.
The louvers are blocked. Install the air conditioner in a location where the louvers are free
from curtains, blinds, furniture, etc.
The outside temperature is below
in the cooling mode when the outside temperature is below 60°F (16°C).
The temperature of the room you are trying to cool is extremely hot. Allow extra time
for the air conditioner to cool off a very hot room.
Windows or doors to the outside are open. Close all windows and doors.
The Exhaust control is set to OPEN (on some models). Push the Exhaust control
CLOSED for maximum cooling.
Depending on model, the Temp/Time or Temperature control is not at a cool enough
setting. Adjust the TEMP/TIME control to a cooler setting by pressing the minus button to
reduce the temperature or adjust the TEMPERATURE control to a cooler setting by turning
the knob clockwise. Set the FAN SPEED control to highest setting (Turbo or High, depen
ding on model).
Water drips from cabinet into your house
The air conditioner is not properly leveled. The air conditioner should slope slightly
downward toward the outside. Level the air conditioner to provide a downward slope toward
the outside to ensure proper drainage. See the Installation Instructions.
NOTE : Do not drill a whole in the bottom of the metal base and condensate pan.
(16°C). Do not try to operate your air conditioner