Step 5: Shoot Bolt Assembly
5.1
Cut the shoot bolts to the required
length as per instructions below:
• Measure the distances as
shown
• Use the formula below and cut
the lengths (lengths include
threaded end piece)
Top Rod (TR) = Panel Height (PH)
- Handle Centre (HC) -98mm
Bottom Rod (BR)
= Handle Centre (HC) -154mm
(Using this formula will result in
the shoot bolts being flush with
the top of the door panel)
5.2
Insert D-bolt into top/bottom of rods
5.3
Crimp D-bolt to retain and hold
5.4
Insert rods from the top and
bottom of the stile and screw
into the lock. Magnets in throw bolts
will assist in locating rods
5.5.
Retain D-bolts in stile to prevent
rotation but allow throw
45
6
11
64
END OF ROD
120
END OF ROD
6
11
45
1800 098 094
ausloc.com