Dynamax SAPIP-LTE 빠른 시작 매뉴얼 - 페이지 7
{카테고리_이름} Dynamax SAPIP-LTE에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dynamax SAPIP-LTE 10 페이지.
ATSM1
The CPU is commanding sleep mode 1 (pin sleep).
ATD51
The CPU is commanding D5=1 (associate light controlled by I/O line 5)
ATAP1
The CPU is commanding API mode
ATWR
The CPU want the module to write the new settings
ATAC
The CPU wants to write all registers to non-volatile memory.
ATCN
The CPU wants to end command mode (AT or transparent mode).
Scanning flash... DEF ATSM=0
Flash memory setup
ATDB
The CPU requests a signal strength reading in dB
Signal: -93dBm
A sample signal strength response
Ready
The CPU is finished setting up the LTE module
ATAP4
The CPU is requesting mini-Pascal mode for getting the date and time from the cell network
>>> import utime as time; time.localtime()
Pascal command to get date and time
(2019, 4, 15, 15, 24, 0, 0, 105)
Sample date/time repsonse
ATAP1
The CPU wants to go back to AT mode
updated Date Time
Update Date and Time is completed
NO SLEEP
Here the LTE module would ordinarily go to sleep but it is being kept awake for this version of the firm-
ware
DEF ATOS=50
ATOW=4000