DIP Switch Settings

NOTE: When DIP switches are set to the "Default" settings, these values can be changed via
Protuner for DM805-AI software.
Dynamic Current Configurations
Peak Current (A)
2.6
3.4
4.0
4.8
5.4
6.1
7.0
Idle Current Reduction
DM805-AI Idle Current Reduction
Idle Current
Reduction
50%
100%
NOTE: Toggle SW4 back and forth twice within one second to enable Auto Tuning.
Pulses/Revolution
DM805-AI Pulses/Revolution (PUL/DIR mode)
Pul/Rev
Default
400
1600
12800
Mode Settings
DM805-AI Mode Settings
Mode
0–5V Speed
LO/HI Speed
External POT
Pulse/Direction
NOTE: Remove power from the drive before changing modes.
Leadshine Stepper Drives Quick Start Guide – First Edition – 11/04/2019
DM805-AI Current Configuration
RMS Current (A)
Default
1.8
2.4
2.8
3.4
3.8
4.3
5.0
SW4
OFF
ON
SW5
SW6
ON
OFF
ON
OFF
SW7
SW8
ON
OFF
ON
OFF
Leadshine Stepper Drives Quick Start Guide
SW1
SW2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
SW3
OFF
OFF
OFF
OFF
ON
ON
ON
ON