AutomationDirect Leadshine DM860E 빠른 시작 매뉴얼 - 페이지 9

{카테고리_이름} AutomationDirect Leadshine DM860E에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. AutomationDirect Leadshine DM860E 17 페이지. Stepper drives

AutomationDirect Leadshine DM860E 빠른 시작 매뉴얼
DM322E Connection to a Sinking Output Controller
Controller
VCC
PUL
DIR
ENABLE
DM322E Connection to Differential Control Signal
Controller
VCC
PUL+
PUL-
DIR+
DIR-
ENA+
ENA-
Note: Although the controller has a pair of
differential outputs (+,-), the + output is not
used in this configuration with the DM322E.

DIP Switch Settings

Dynamic Current Configurations
Peak Current (A)
0.3
0.5
0.7
1.0
1.3
1.6
1.9
2.2
Leadshine Stepper Drives Quick Start Guide – First Edition – 11/04/2019
R=0 if VCC=5V
R=1K(Power>0.125W) if VCC=12V
R=2K(Power>0.125W) if VCC=24V
R must be connected to control signal terminal
R
R
R
Power Supply
Stepping
Motor
R=0 if VCC=5V
R=1K(Power>0.125W) if VCC=12V
R=2K(Power>0.125W) if VCC=24V
R must be connected to control signal terminal
R
R
R
Power Supply
Stepping
Motor
DM322E Current Configuration
RMS Current (A)
0.21
0.35
0.49
0.71
0.92
1.13
1.34
1.56
Leadshine Stepper Drives Quick Start Guide
DM322E Driver
270 Ω
OPTO
PUL
270 Ω
DIR
270 Ω
ENA
VDC
GND
A+
A-
B+
B-
DM322E Driver
270Ω
OPTO
PUL
270 Ω
DIR
270 Ω
ENA
VDC
GND
A+
A-
B+
B-
SW1
SW2
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
SW3
ON
ON
ON
ON
OFF
OFF
OFF
OFF
Page 9 of 17