Full Cleaning Cycle
1. We recommend a complete cleaning every 6-12 months.
2. First, unplug the power supply.Open the back shroud. Pull out the ionization wire frame and collecting plates.
Pull out the protective rubber sleeve as illustrated (in Pic 1).
3. Clean the ionization wire frame very gently with a soft sponge, wiping in 1 direction, and clean the collecting plates
with water and a rag.
4. Use a wet cloth to wipe down all surfaces of the protective rubber sleeve, including notches. For better results,
wash the entire rubber sleeve in water.
5. Clean the inner walls of the air purifier with a soft cloth (Pic 2).
6. Wash the pre-filter in water, clean it by vacuum, or brush it gently with a soft brush.
7. Dry the parts completely, 100% dry, and then put them back in order.
Pic 1
Pic 2
Air Quality Sensor Cleaning
Airdog air purifier has an embedded air quality sensor. To keep
the air quality sensor reading correctly, please clean the sensor
every 6 months, using a dry soft rag or cotton swabs with
rubbing alcohol as illustrated.
Reminder
1. Please take out the line cord directly from the back (Pic 1). DO NOT coil or run the power cord under the bottom
of the air purifier. Keep it free and clear from obstructions (Pic 2, Pic3).
2. ONLY use the original adapter.
3. Follow the instructions above to avoid creating problems with the electromagnetic compatibility of the purifier.
Pic 1 Correct
Pic 2 Wrong
Pic 1
Pic 3 Wrong