Soffit Installation

SOFFIT FOR DCS-IVH-36 ISLAND VENT HOOD
The dimensions given are for a 1/2 inch drywall.
1) Create a soffit structure and attach the soffit brackets as in figure 1. Refer to the installation
guidelines on Page 7.
2) Attach the soffit support bars as shown in figure 2.
3) After securing the soffit structure adequately to the ceiling joist, attach the Island Vent Hood
with the mounting screws provided, figure 3.
Refer to page 7 on finishing the installation.
Create your Soffit Structures
first and attach Soffit Brackets
to each side with screws provided
SOFFIT ASSEMBLY
FOR 36" ISLAND VENT HOOD
SUPPORT
HEIGHT WILL
VARY
BARS
ACCORDING
TO CEILING
HEIGHT
16 3/4 "
10 3/4 "
The dimensions given
are for a 1/2 " drywall.
FIG.1
FIG.2
8
CREATE YOUR
SOFFIT STRUCTURE
ACCORDING TO THE
CEILING HEIGHT
THEN ATTACH IT
TO THE CEILING JOIST.
SCREW SUPPORT BARS
ON BOTH SIDES AS SHOWN
SOFFIT BRACKETS
SCREWED TO BOTH SIDES
OF SOFFIT STRUCTURE
36" ISLAND VENT HOOD SOFFIT MOUNTING
FIG.3
6 Mounting Screws