REPLACING THE BALLAST

• UV Light in operation; disconnect unit from power cord before servicing; failure
to follow warnings may result in severe eye damage
• Disconnect power at the breaker or fuse panel before servicing unit;
always follow OSHA lockout procedures to prevent accidental exposure to
electrical energy
WARNING
Power
Cord
1. Disconnect (unplug) power cord from unit.
NOTE: Always follow OHSA electrical lockout safety requirements to prevent accidental release of energy
during service or maintenance activities.
3. Disconnect all ballast wiring by pressing
down on connector tabs and pulling wire
straight out.
5. Place new ballast into original location and secure using the two (2) nuts removed in step 4.
2. Open the ballast housing by removing the
four (4) screws then removing the cover.
4. Remove the two (2) nuts securing ballast to
the case. Remove the ballast.