Interrupts
Interrupts from the PMCs are connected from the PMC to the primary PCI bus.
INTA - INTD are mapped directly to the primary bus segment for position 0 and
"rotated" B, C, D, A for position 1.
cPCI
Position 0
INTA
INTA
INTB
INTB
INTC
INTC
INTD
INTD
Options
Dynamic Engineering offers options to the cPCIBPMC6U design.
When -RIO is added to the part number the rear IO option is installed [J04, J14,
J3, J5]. Routing between J3 ó J04 & J5 ó J14 provides the connection.
routing is controlled impedance, and matched length. Routed as differential parts
with 100 ohm impedance for each pair.
Fans can be added where high power PMCs are used or inadequate in chassis
circulation is present.
JTAG support is available. The JTAG header position is clearly marked in the
silk screen. The header is frequently not used and is not installed unless
requested.
The Bridge supports a GPIO function. A header position is available with the
positions clearly marked in the silk-screen. The header is installed by request.
Please contact Dynamic Engineering for this option. The 4 bits are terminated
with 4.7KΩ to 3.3V.
Other Signals
PME is pulled up with a 10K ohm resistor to 3.3V.
Reset Out on PMC position is open.
Position 1
INTB
INTC
INTD
INTA