Specifications

Logic Interface:
CompactFLASH:
Software Interface:
Initialization:
Access Modes:
Access Time:
Interrupt:
DMA:
Onboard Options:
Interface Options:
Dimensions:
Construction:
Temperature Coefficient:
Power:
IP Module Logic Interface
One CompactFLASH compatible socket provided. External transition module
can be used to add a second module.
Control Registers, ID PROM, Vector Register, Status Ports
Hardware Reset forces all registers to 0.
Word I/O Space (see memory map)
Word in ID Space
Vectored interrupt
Access time depends on CompactFLASH Module. back-to-back cycles in 500ns
(8Mhz.) or 125 nS (32 Mhz.) for internal operations. Approximately 1 uS for
CompactFLASH accesses. Write operations are posted and return for pipelined
operation. Read accesses are data delayed.
Masked or polled operation. Master interrupt enable and status. INTRQ0 only.
No Logic Interface DMA Support implemented at this time.
All Options are Software Programmable
50 pin flat cable
50 screw terminal block interface [HDRterm50]
User cable
none required.
Standard Single IP Module. 1.8 x 3.9 x 0.344 (max.) inches
FR4 Multi-Layer Printed Circuit, Through Hole and Surface Mount Components.
Programmable parts are socketed.
0.89 W/ o C for uniform heat across IP
Max. TBD mA @ 5
E m b e d d e d
S o l u t i o n s
P g
1 9
o f
2 0