The electrical installation must comply with low voltage regulations and with the corresponding
regulations of each country.
1. Installation
Electrical connections must provide a minimum of
Ipx5 protection within volume 1. A connecting box (in
accordance with the protection established) is
recommended. Care must also be taken to make this
connection at a height of more than 20 mm above the
floor.
No part of the bath should be situated above it while in
use.
Sections containing live parts, except those powered
by a very low safe voltage that does not exceed 12 V,
must be inaccessible to a person inside the bath.
No switches, power sockets or light fittings shall be
installed in volumes 0 and 1. Above these volumes it
shall be permissible to have sound control contactors
operated by a draw-cord or chain of non-hygroscopic
material.
Switches shall not be installed in volume 2, however
safety power sockets can be installed. Fixed light
fittings may also be installed, preferably with category
II insulation or, if unavailable, install those which do
not have any accessible metallic part. In the lamp
holders it shall not be possible to make any accidental
contact with live parts when inserting or removing
bulbs. In such light fittings no switches or power
sockets are allowed, except if these are safety power
sockets.
2. Wiring
The power cable used must be the one supplied with the bath or another of similar characteristics (with
the cover having characteristics not inferior to type H05 V V-F), taking into account the maximum voltage
stipulated in the low voltage regulations. The section of cable supplied is 1,5 mm .
The bath must be permanently connected to the electrical mains, with no extensions, and to the earth
installation. The use of a plug socket is not acceptable. Therefore, an electrical junction box must be
provided for connecting to the cable that supplies the bath. Said box will be of IPx5 type, fitted 20 cm
above the ground.
Installation manual

ELECTRICAL INSTALLATION

Volume 0
Volume 0
Volume 1
2
24 9
Fig-3