Dynamic Precision DPA 6.4 사용자 설명서 - 페이지 11

{카테고리_이름} Dynamic Precision DPA 6.4에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Dynamic Precision DPA 6.4 13 페이지.

SYMPTOM
Apparatus is put in STANDBY.
Humming sound heard from the
loudspeakers.
No sound, but the indicators are
lit.
DPA 6.4
POSSIBLE CAUSE
1: High frequency noise
2: Problem with the signal cable.
3: DC on the inputs.
4: Overheating.
5: Strong signal clipping.
Degraded/defective shield on the
signal cables.
Fuses (T5A) may be defective.

TROUBLESHOOTING

POSSIBLE SOLUTION
1: Insert a mains filter between
the power amplifier and the
main outlet.
2: Check for proper
grounding/shield of the cables,
or replace the cables.
3: Check if DC is present on
the signal source output.
4a: Check if the loudspeaker
cables are partially short-
circuited, or replace the
cables.
4b: Ensure that the amplifier
has at least 15 cm of free
space on top.
5: Input level is too high.
Check or replace the cables.
Replace the fuses and check
the apparatus for proper
operation. Check if the
loudspeaker cables are wired
correctly and/or if a shortening-
circuit has occurred.
10
PAGE