Automotive Data Solutions RSA-SUB2 설치 매뉴얼 - 페이지 11

{카테고리_이름} Automotive Data Solutions RSA-SUB2에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Automotive Data Solutions RSA-SUB2 13 페이지. 2017 subaru crosstrek pts automatic

Automotive Data Solutions RSA-SUB2 설치 매뉴얼
REMOTE STARTER ERROR CODES: NOTES
I WARNING: The following applies only when the parking lights are
connected and supported by the system.
II After a remote starter failure, the parking lights will flash three [3x]
times followed by the error code. See table.
REMOTE STARTER SHUTDOWN ERROR CODES: NOTES
I WARNING: The following applies only when the parking lights are
connected and supported by the system.
II If the engine shuts down after a remote starter sequence
use the query command from a compatible aftermarket
remote to display the shutdown error code. The parking lights will
flash four [4x] times followed by the error code. See table.
U.S. Patent No. 8,856,780 CA 2759622
Automotive Data Solutions Inc. © 2022
REMOTE STARTER ERROR CODES - 1 OF 1
PARKING LIGHT FLASHES
DIAGNOSTIC
3 + 1
Tach is not programmed OR engine is already running.
3 + 2
Key is in ignition ON position.
3 + 3
Door is open.
3 + 4
Trunk is open.
3 + 5
Foot brake is ON.
3 + 6
Hood is open.
3 + 7
Loop is not cut.
3 + 8
No tach detected.
3 + 9
Vehicle movement detected (VSS).
3 + 10
System is in Valet Mode.
3 + 11
CAN communication failure
3 + 12
RS not synchronized. Start vehicle with OEM key for 15 sec before trying a new RS sequence.
3 + 13
Bypass problem.
3 + 14
Idle mode or takeover is not available on this vehicle.
3 + 15
Overheat protection.
PARKING LIGHT FLASHES
DIAGNOSTIC
4 + 1
Engine tach signal was lost.
4 + 2
Emergency brake signal was lost.
4 + 3
Foot brake ON detected.
4 + 4
Hood open detected.
4 + 5
Tach over rev detected.
4 + 6
Glow plug timeout error.
4 + 7
Vehicle movement detected (VSS).
4 + 8
Check engine light ON.
4 + 9
Low fuel level.
4 + 10
Open door detected.
4 + 11
CAN communication failure during RS sequence.
4 + 12
RS not synchronized. Start vehicle with OEM key for 15 sec before trying a new RS sequence.
4 + 13
Bypass problem.
4 + 14
Idle mode or takeover is not available on this vehicle.
4 + 15
Overheat protection.