Shown with wooden box & optional back board support
option 1
Step 3: Adjust Limit Switches
The Auton lift utilizes limit switches to
control your preferred positioning of the unit.
The limit switches are located on the motor.
The top switch controls the lift's ending
position and the bottom switch controls
the lift's starting position.
Turn the adjusting screw with a hex key or flathead screwdriver. To prevent over-adjustment, turn screw
in very small increments. Each full turn of the screw corresponds to 3/8" in travel.
Using a power tool to adjust the limits will void the warranty.
A.
STARTING POSITION: Turn the bottom screw clockwise to raise the lift's starting position.
Turn the screw counterclockwise to lower the lift's starting position.
B.
ENDING POSITION: Turn the top screw clockwise to allow the lift to lower more.
Turn the screw counterclockwise to raise the lifts position.
C.
To test positioning run the lift approximately 6" in the opposite direction, stop and then reverse lift motion.
*If positioning requires more than 5 cycles of the lift, the built-in thermal overload protector will disable the
motor to prevent overheating and possible damage. The unit will automatically re-set itself within 10-15minutes.
option 2
ENDING POSITION
STARTING POSITION
Caution:
Dropping or jarring unit by
hitting walls, ceilings, or
other objects may cause
misalignment of lift.
+ -
- +