8STREME 5220-LUNA 10 매뉴얼 - 페이지 13

{카테고리_이름} 8STREME 5220-LUNA 10에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. 8STREME 5220-LUNA 10 18 페이지.

8STREME 5220-LUNA 10 매뉴얼
EN
10 Troubles hooting
Page 13
PROBLEM
The robot floats on the surface.
The robot does not clean all areas of the pool.
The robot does not recover debris during operation.
Fine particles (dust or dirt, pollen ...) are ejected by
the impeller.
- Immersion of the robot in the pool.
- Use of the fine filter.
- Not enough / too much cable floating in the pool.
- The robot does not receive enough power.
- Basket clogged / full.
- An object is stuck in the impellers or the grids
located in front of the impeller.
- Debris are too fine, the robot is made to pick up
the particles more than 50 microns (with the fine
filter inside the basket).
CAUS E(S)
- When you put the robot in the pool, let it sink and
reach the floor before you turn it on.
- If you use an optional fine filter, remove the filter
from its plastic wrap, immerse the filter in the water
so that it is already wet before you put it in the robot
and let the robot settle on the floor before you
turn it on.
- Make sure the length of floating cable introduced
in the pool is just the required length.
- Remove any excess cable length from the pool and
leave this excess length outside the pool next to the
power supply box.
- Insert the robot at the center point of the pool.
If your pool is oval or rectangular, this point is the
middle of the length.
- Check the connection of the cables.
- Clean the basket and filter panel. Clean the fine
filter if you use this accessory.
- Check if the basket is properly inserted. (See
chapter Cleaning of the filter basket).
- Check that there are no foreign objects in the
impellers or blocked in the grid in front of the
impellers
- Check the attachment of the basket, press it if
necessary to lock it.
- Use a fine filter (check item number on the parts
drawing 19, sku 51390 filters) on the
other hand do not forget that it is the filtration of
your swimming pool which ensures the cleaning of
the particles of less than 50 microns.