Autonics BS5 Series 제품 설명서

{카테고리_이름} Autonics BS5 Series에 대한 제품 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Autonics BS5 Series 4 페이지. Groove-depth 9 mm photomicro sensors

Autonics BS5 Series 제품 설명서
TCD210205AB
Groove-Depth 9 mm
Photomicro Sensors
BS5 Series
PRODUCT MANUAL
For your safety, read and follow the considerations written in the instruction
manual, other manuals and Autonics website.
The specifications, dimensions, etc. are subject to change without notice for product
improvement. Some models may be discontinued without notice.
Features
• Select appearance depending on the install location (K, T, V, L, Y, F, R, TA type)
• Minimize malfunction and improve visibility
- Minimize sensing part, gap and flush of the body to reduce malfunctions
caused by a foreign substance
- Built-in U-shaped indicator can be checked in many directions
• Selectable models for the operation of indicator
- Indicator turns ON under the light received condition
- Indicator turns ON under the light interrupted condition
• Resistant structure for shock and vibration
- Shock 15,000 m/s
(approx. 1,500 G), vibration 10 to 2,000 Hz (1.5 mm amplitude)
2
• Selectable operation modes (Light ON/Dark ON) via connector or control wire
• High-frequency response : 2 kHz
Safety Considerations
• Observe all 'Safety Considerations' for safe and proper operation to avoid hazards.
• ᜸ symbol indicates caution due to special circumstances in which hazards may occur.
᜸ Warning
Failure to follow instructions may result in serious injury or death.
01. Fail-safe device must be installed when using the unit with machinery that
may cause serious injury or substantial economic loss. (e.g., nuclear power
control, medical equipment, ships, vehicles, railways, aircraft, combustion
apparatus, safety equipment, crime/disaster prevention devices, etc.)
Failure to follow this instruction may result in personal injury, fire or economic loss.
02. Do not use the unit in the place where flammable/explosive/corrosive gas,
high humidity, direct sunlight, radiant heat, vibration, impact, or salinity
may be present.
Failure to follow this instruction may result in explosion or fire.
03. Do not disassemble or modify the unit.
Failure to follow this instruction may result in fire.
04. Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in fire.
05. Check 'Connections' before wiring.
Failure to follow this instruction may result in fire.
᜸ Caution
Failure to follow instructions may result in injury or product damage.
01. Use the unit within the rated specifications.
Failure to follow this instruction may result in fire or shortening the life cycle of the
product.
02. Use dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in fire or electric shock.
Cautions during Use
• Follow instructions in 'Cautions during Use' . Otherwise, It may cause unexpected
accidents.
• Use the product, 0.5 sec after supplying power. When using separate power supply for
the sensor and load, supply power to sensor first.
• 5-24 VDCᜡ power supply should be insulated and limited voltage/current or Class 2,
SELV power supply device.
• Wire as short as possible and keep away from high voltage lines or power lines, to
prevent inductive noise.
• When using sensor with the equipment which generates noise (switching regulator,
inverter, servo motor, etc.), ground F.G. terminal of the equipment.
• This unit may be used in the following environments.
-
Indoors (in the environment condition rated in 'Specifications')
- Altitude max. 2,000m
- Pollution degree 2
- Installation category II