{카테고리_이름} Cell2 SAS32R에 대한 설치 및 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cell2 SAS32R 8 페이지. Speaker siren system w/ control switch & mic set

PA BROADCAST

PA Activation
Press "Push-to-Talk" button on the side of the Mic to activate
PA broadcasting. PA broadcasting will override all current
Siren Tone. Action will resume when PTT is released.
Mic Volume Adjustment Knob
(available on selected mic model only)
The knob located on the top right corner of the controller will
adjust mic volume (high or low). Turn clockwise for high
volume; turn anticlockwise for low volume.

LOW VOLTAGE PROTECTION MODE

While unit is in operation, whenever power voltage drops under 11.6VDC for over 10
seconds, SW300 controller will blink to notify Low Voltage issue is at presence; all controller
function will be disabled.
If Low Voltage issue continued for another 10 seconds, all Siren function will be disabled
automatically and entre Low Voltage Protection Mode.
While unit is in Low Voltage Protection Mode, if power voltage resumes back to 13VDC and
above for over 10 seconds, Siren unit will exit Low Voltage Protection Mode and back to its
default standby.
- 7 -
Handheld Mic
PTT
Clip-on Mic
PTT
Mic Volume
Adjustment Knob