DBK Drymatic Boost Bar FGPH107 사용 설명서 - 페이지 15

{카테고리_이름} DBK Drymatic Boost Bar FGPH107에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. DBK Drymatic Boost Bar FGPH107 18 페이지. Adaptable heat drying system

Trouble Shooting:
In the event of a fault the first thing to try is powering down the machine, turning off the power at the mains and then waiting
ten seconds. You can then power it up again and see if there are any improvements. If not please refer to this troubleshooting
table for causes and solutions.
Fault
No power, red power switch is not
illuminated when in on position.
No display, red power switch
illuminates when in on position.
Unit not producing warm airflow. Fan
symbol is marked with a X
Unit not producing hot air. No Rotating
graphic is shown in hours display.
Drymatic Wall and Floor System not
inflating
In the event that this list does not cover your particular issue or the solution does not solve the problem
please contact your local Drymatic representative.
Cause
1) Plug fuse blown.
2) Fault with mains outlet or cord.
1) Internal fuse blown.
1) Insufficient airflow
1) Machine has not had sufficient time
to heat up.
2) Temperature setting is lower than
room ambient.
1) Insufficient airflow
14
Solution
Check plug fuse, if plug type doesn't
have a fuse contact service.
Check supply output and check cord for
any damage, breaks or cuts. If cord is
damaged seek replacement.
Check Internal fuse, it is located on the
switch panel next to the red power
switch. Replace if necessary.
Try positioning the air mover closer to
the Drymatic Boost Bar or use a higher
speed setting. Check that the air mover
meets the minimum requirements.
The machine will check for stable
airflow before gradually ramping up
power. This can take up to five
minutes.
Increase the temperature setting, it
may be that the room is hotter than
the temperature limit set.
Try positioning the air mover closer to
the Drymatic Boost Bar or use a higher
speed setting. Check that the mat is
well sealed around the Drymatic Boost
Bar and free to inflate. The minimum
recommended airflow of 1100m³/Hr
(650 cfm) is the requirement for the
Drymatic
Boost
Bar
correctly. Inflating mats, depending on
configuration, may require significantly
to
function