remote site.
3. The equipment will monitor the status of optical link, either transmitting alarm or
receiving alarm will be taken as an optical link fault. At the mean time, the Ethernet
interface status will change to link down and the E1 interface will be cut off. The
Ethernet interface and E1 interface will not recover until the optical interface
recovers.
The fault-pass-through capability is designed for users who have particular requirements.
When it is disabled, any fault at remote site and at optical interface has nothing to do with
local interfaces; all the interfaces of local module will be open.
In order to avoid misunderstanding, users are advised to use it cautiously. The factory
default status is disabled.
3.2.3 E1 Remote Loop-back Test
"E1 remote loop-back" setup at local Ethernet Multiplexer
Note: when setup any kinds of loop-back at the local Ethernet Multiplexer, the "remote
loop-back" switch at remote Ethernet Multiplexer must be at default status. When the
module is at E1 remote loop-back status, the Ethernet data communication will not be
interfered.
3.2.4 How to Implement Remote Network Management
When the equipment is connected as the following topology, the remote network
management can be implemented.
The host-site module is installed in Dynamix's dedicated 16-slot 3U-high chassis,
A.
which also has the network management module installed. The remote-site module
is installed in Dynamix's single slot chassis.