OPERATING ANGLE-TYPE SERVICE VALVE
1 - Remove stem cap with an appropriately sized wrench.
2 - Use a service wrench with a hex-head extension (3/16" for liquid
line valve sizes and 5/16" for vapor line valve sizes) to back the
stem out counterclockwise as far as it will go.
SERVICE PORT CAP
SERVICE PORT CORE
When service valve is OPEN, the service port is
open to line set, indoor and outdoor unit.
When service valve is CLOSED, the service port is
open to the line set and indoor unit.
NOTE - A label with specific torque requirements may be affixed to
the stem cap. If the label is present, use the specified torque.
FIGURE 15
ACCESS SERVICE PORT
A service port cap protects the service port core from contamination
and serves as the primary leak seal.
1 - Remove service port cap with an appropriately sized wrench.
2 - Connect gauge set to service port.
3 - When testing is completed, replace service port cap and tighten
as follows:
With torque wrench, finger tighten and torque
cap per table 2.
Without torque wrench, finger tighten and
use an appropriately sized wrench to turn
an additional 1/6 turn clockwise.
Reinstall Stem Cap
Stem cap protects the valve stem from damage and serves as the
primary seal. Replace the stem cap and tighten as follows:
With torque wrench, finger tighten and
then torque cap per table 2.
Without torque wrench, fi
en and use an appropriately sized
wrench to turn an additional 1/12
turn clockwise.
FIGURE 16
(VALVE STEM SHOWN OPEN)
INSERT HEX WRENCH HERE
STEM CAP
ANGLE-TYPE SERVICE VALVE
(BACK-SEATED OPENED)
(VALVE STEM SHOWN CLOSED)
INSERT HEX WRENCH HERE
ANGLE-TYPE SERVICE VALVE
(FRONT-SEATED CLOSED)
1/6 TURN
11 12
1
10
9
8
5
7
6
1/12 TURN
11 12
1
2
10
9
4
8
7
5
6
Checking and Adding System Charge
The 4AC14 unit is factory-charged with enough HFC-410A
refrigerant to accommodate a 15-foot length of refrigerant
piping. Charge should be checked and adjusted using the
tables provided on the charging procedure sticker located
on the unit access panel. Detailed information is provided
in the 4AC14 Installation and Service Procedures manual.
Homeowner Information
Before attempting to perform any service or maintenance,
turn the electrical power to unit OFF at disconnect switch.
In order to ensure peak performance, your system must
be properly maintained. Clogged filters and blocked air-
flow prevent your unit from operating at its most efficient
level. The system should be inspected and serviced be-
fore each cooling and heating season by a licensed pro-
fessional HVAC service technician (or equivalent).
The following maintenance may be performed by the
homeowner.
• Contact a licensed professional HVAC technician to
schedule inspection and maintenance appointments for
your equipment before each heating and cooling sea-
son.
• Check the indoor unit filter each month and replace the
filter, if necessary.
• Have your dealer show you where your indoor unit filter
is located. It will be either at the indoor unit (installed
internal or external to the cabinet) or behind a return air
grille in the wall or ceiling. Check the filter monthly and
clean or replace it as needed. Disposable filters should
be replaced with a filter of the same type and size.
• Check the indoor unit drain line for obstructions month-
ly. The indoor coil is equipped with a drain pan to collect
condensate formed as your system removes humidity
from the inside air. Have your dealer show you the loca-
2
tion of the drain line and how to check for obstructions.
3
(This would also apply to an auxiliary drain, if installed.)
4
• Check the area around the outdoor unit monthly and
remove any obstructions that may restrict airflow to the
outdoor unit. This would include grass clippings, leaves,
or papers that may have settled around the unit.
• Trim shrubbery away from the unit and periodically
check for debris which collects around the unit.
• During the winter months, keep the snow level below
3
the louvered panels.
NOTE - The filter and all access panels must be in place
any time the unit is in operation. If you are unsure about
the filter required for your system, call your dealer for as-
sistance.