Cleaning of Coolant side
In some applications, the fouling tendency can be very high, e.g.
when using extremely hard water at high temperatures. In such
cases, it is always possible to clean the Compact by:
Circulating a cleaning liquid (CIP - Cleaning In Place).
-
A solution of 5 % phosphoric acid or 5 % oxalic acid in water is
-
recommended to chemically clean the channels.
The flow rate of the cleaning liquid should be greater than the
-
design coolant flow, and it should flow in the reverse
direction through the heat exchanger compared to the
normal operation flow direction.
ATTENTION! After the cleaning process, it is very important that
-
the heat exchanger is flushed thoroughly with clean water before
start-up.
Cleaning of Gas side
Heavy condensation can have a self-cleaning effect, washing the
Compact and reducing fouling on the gas side. In applications
where the gas contains elements of soot, grease or oil residues
the risk of clogging the gas channel can be high. In such cases, it is
always possible to clean the Compact by:
Blocking the gas connections.
-
Circulating a cleaning liquid (CIP - Cleaning In Place) either
-
through the condensate connections or (if the fouling issue
have been addressed in the design phase) through specially
designed connections on the connecting pipes.
A suitable CIP-solution for the residues from the gas should
be used.
ATTENTION! Chemicals known to corrode copper (i.e. ammonia,
-
sulphur, etc.) are strictly forbidden to use as cleaning agent.
The flow rate of the cleaning liquid should be greater than the
-
design gas flow, and it should flow in the reverse direction
through the heat exchanger compared to the normal
operation flow direction.
ATTENTION! After the cleaning process it is very important that
-
the heat exchanger is flushed thoroughly with clean water before
start-up.
Warranty
Airec offers a 12-month warranty from the date of installation, but
in no case longer than 18 months from the date of delivery. The
warranty covers only manufacturing and material defects (poor
workmanship and/or faulty material). The warranty does not
cover damage caused by mechanical (including fatigue damage
due to vibrations/pulsations) and/or thermal stress.
The warranty does not cover damage caused by corrosion.
The warranty does not cover damages caused by dirt build up
and/or fouling.
For further information please see
load.
Storage
The Compact shall always be stored in a dry and protective
environment. The temperature should not be below 1°C and not
over 50°C for long term storage (more than 4 weeks).
At long operational stand-by periods the system should be
inspected for contamination on Liquid and Gas side, if necessary
clean the Compact according to the cleaning instructions. Liquid
side with water should be drained.
Disclaimer
The Compact
performance is based on installation, maintenance
and operating conditions done in conformance with this manual.
Airec cannot assume any liability for Compact heat exchangers
that do not meet these criteria.
Declaration of Conformity
It is hereby confirmed that the products Compact family has been
designed, manufactured, tested and documented to fulfil the
category requirements in the Pressure Equipment Directive
2014/68/EU, module B (production) + D (no. 15-1002306-100). The
products have been designed according to standard 13445.
Notified body: Inspecta 0409, PO Box 30100, SE-104 25 Stockholm,
Sweden.
Further information on the product identification label on
respective product.
AIREC AB
Signature:
Michael Bäärnhielm
For further information, please consult Airec's technical information
or your local Airec representative.
AIREC AB
Hanögatan 5
SE-211 24 Malmö, Sweden
switch: +46 (0)40 93 63 60
www.airec.com
www.airec.com/support/down-