Autonics MX4W Series 제품 설명서 - 페이지 6
{카테고리_이름} Autonics MX4W Series에 대한 제품 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Autonics MX4W Series 6 페이지. Lcd multi panel meters
Function Description
■ Display method: frequency
It measures input signal frequency when it is AC input.
In order to measure frequency normally, input signal, over 10 % F.S. of the rated input range,
should be supplied. Otherwise, it may not be measured normally.
The measurement range differs depending on the decimal point position.
It is available to adjust the high-limit display value gradient correction and exponent of SPAN at
parameter setting.
• Accuracy of frequency measurement: below 1 kHz: F.S. ± 0.1 % rdg ± 2-digit,
from 1 k to 10 kHz: F.S. ± 0.3 % rdg ± 2-digit
■ High-limit display value gradient correction
This function is to correct a gradient of high / low-limit scale value.
And also can be used as correction function of high-limit scale value.
Adjustment range is setting value and multiply current gradient.
• E.g.: To display 5.000 when 20 VDCᜡ for input range 0.00 - 50.00 VDCᜡ
12.500
Display value for
Display value for
5.000
measuring input
measuring input
20
50V
Input value
1. Select input range = 50.0, decimal point position = 0.000 for measurement input in Parameter 1.
2. It has to be 12.500 at high-limit scale for 50 VDCᜡ in order to display 5.000 for 20 VDCᜡ.
But it is disable due to setting range is 9.999.
3. In this case, set as high-limit display value gradient correction × high-limit scale = 12.500.
• E.g.: To display -160.0 when -80 mA for input range -200 - 200 mA
Display value
400.0
Display value for
Display value for
measuring input
measuring input
160.0
Input value
-200.0 -80.0
80.0 200.0
-160.0
-400.0
1. Select input type = -DC, input range = -200, decimal point position = 000.0 for measurement
input in Parameter 1.
2. If set to display -80 mA as -160.0, the low-limit scale value ×high-limit display value gradient
correction at -200 mA must be -400.0. But it is disable due to setting range is 9.999.
3. In this case, set as high-limit display value gradient correction × high-limit scale = 400.0 and
high-limit display value gradient correction × low-limit scale = -400.0.
• If the low-limit scale is set first set the high-limit scale = - (low-limit scale).
If the high-limit scale is set first set the low-limit scale = - (high-limit scale).
■ High / Low-limit scale value
This function is to display setting of particular high / low-limit value in order to display high /
low-limit value of measured input.
If measured inputs are a and b and particular values are A and B, it will display a = A, b = B as
below graphs.
• When changing input range, it is changed automatically as factory default display range of
the input range.
Display
Display
value
value
B
B
A
A
a
b
a
Input
value
Display
Display
value
value
a
A
A
B
B
a
b
Input
value
Display
Display
value
value
B
B
a
b
a
Input
A
A
value
• In case of DC voltage / current input model and using minus input,
they are displayed.
■ Zero adjustment
It adjusts the display value of the optional configured input value as zero by force.
Zero point error can be adjusted with 3 ways as below.
1. Direct input correction value at low-limit display value deviation correction parameter.
2. Press the [◀] + [▲] keys for 3 sec in RUN mode.
3. Set the external input terminal parameter to ZERO and short the Hold / Zero terminal.
H-SC
L-SC
SPAN
Result
12.500 0.000
1.000
Disable
6.250
0.000
2.000
20 VDCᜡ
3.125
0.000
4.000
= 5.000
2.500
0.000
5.000
H-SC
L-SC
SPAN
Result
400.0
-400.0
1.000
200.0
-200.0
2.000
-80 mA
= -160.0
100.0
-100.0
4.000
80.0
-80.0
5.000
Display
value
B
a
b
Input
A
b
Input
value
value
Display
value
b
A
a
b
Input
value
Input
value
B
Display
value
A
b
b
Input
a
Input
value
value
B
■ Error correction
It corrects display value error of measured input.
Display value = (Measured value × High-limit display value gradient correction)
+ Low-limit display value deviation correction
• E.g.: When the input range 0 to 500 VDCᜡ and the display range is 0 to 500.0
If the low-limit display value is 1.2 to 0 VDCᜡ input, set -12 as deviation correction value to
display 0.0 by adjusting offset of the low-limit display value.
The display value to 500 VDCᜡ measured input varies by adjusting the offset of low-limit
display value.
If this display value is 501.0, calculate 500.0 / 501.0 (desired display value / the display value),
and set the 0.998 correction value as the high-limit display value gradient correction parameter
to display 500.0 by adjusting gradient of high-limit value.
■ Startup compensation time
This time function limits the operation of an output until the measured input (overvoltage
or inrush current) is stable at moment of power on. All outputs are OFF during startup
compensation time setting after power is applied.
■ Display cycle
In some applications the measured input may fluctuate which in turn causes the display to
fluctuate.
By adjusting the display cycle delay function time the operator can adjust the display time.
For example, if the operator sets the display cycle time to 4 sec, the display value displayed
will be the average input value over 4 sec and also will show any changes if any every 4 sec.
■ Max. / Min. peak value
It monitors max./min. peak value of display value based on the current displays value and then
displays the data at the parameters. When pressing the front direction keys at the same time
for over 1 sec at the parameters, the monitored data is initialized.
Set the delay time at peak monitoring delay time parameter in order to prevent malfunction
caused by initial overcurrent or overvoltage, when monitoring the peak value.
Segment Table
The segments displayed on the product indicate the following meanings. It may differ
depending on the product.
7 segment
11 segment
0
I
0
0
0
I
1
J
1
1
1
J
2
K
2
2
2
K
3
L
3
3
3
L
4
M
4
4
4
M
5
N
5
5
5
N
6
O
6
6
6
O
7
P
7
7
7
P
8
Q
8
8
8
Q
9
R
9
9
9
R
A
S
A
A
A
S
B
T
B
B
B
T
C
U
C
C
C
U
D
V
D
D
D
V
E
W
E
E
E
W
F
X
F
F
F
X
G
Y
G
G
G
Y
H
Z
H
H
H
Z
18, Bansong-ro 513Beon-gil, Haeundae-gu, Busan, Republic of Korea, 48002
www.autonics.com | +82-51-519-3232 | [email protected]
12 segment
16 segment
I
0
I
0
I
0
I
0
I
J
1
J
1
J
1
J
1
J
K
2
K
2
K
2
K
2
K
L
3
L
3
L
3
L
3
L
M
4
M
4
M
4
M
4
M
N
5
N
5
N
5
N
5
N
O
6
O
6
O
6
O
6
O
P
7
P
7
P
7
P
7
P
Q
8
Q
8
Q
8
Q
8
Q
R
9
R
9
R
9
R
9
R
S
A
S
A
S
A
S
A
S
T
B
T
B
T
B
T
B
T
U
C
U
C
U
C
U
C
U
V
D
V
D
V
D
V
D
V
W
E
W
E
W
E
W
E
W
X
F
X
F
X
F
X
F
X
Y
G
Y
G
Y
G
Y
G
Y
Z
H
Z
H
Z
H
Z
H
Z
-
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z