969.Coffee Artika 매뉴얼 - 페이지 4
{카테고리_이름} 969.Coffee Artika에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. 969.Coffee Artika 7 페이지.
The pump is controlled by a relay with a 10-Amp contact, whereas the solenoid valve is controlled by a relay with an 8
amp contact.
The high/voltage connections of the volumetric meters and the level probe are made with 6.38mm faston connectors,
whereas the connections to the push button panels and the serial transmission are made with model II AMP
connectors.
All of the components are UL/VDE/CSA approved.
The control unit is built to standard CEI 61-150 (European Standard EN 60 335-1) on safety of household and similar
electrical appliances.
The operating room temperature range is between 0°C (32°F) and 70°C (158°F).
Installation
After removing the machine from its package and before the authorized technician arrives to install it:
•
Place it in a safe and stable position in its chosen location, making sure that:
the worktop is suitable for supporting the machine's weight and is leveled (maximum inclination 3°).
-
If necessary, adjust the mobile part of the feet;
-
there is necessary space to carry out all preliminary and future maintenance operations.
-
Place the water drain and the electrical and hydraulic connections max 1 meter from the worktop
WARNING!
The machine is designed for indoor installation.
Therefore it should not be exposed to rain, strong sources of heat, and/or other atmospheric agents.
The machine should be connected to a grounded outlet.
4