iHealth BP5 소유자 매뉴얼 - 페이지 7

{카테고리_이름} iHealth BP5에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. iHealth BP5 13 페이지. Wireless blood pressure monitor
iHealth BP5에 대해서도 마찬가지입니다: 소유자 매뉴얼 (17 페이지), 빠른 시작 매뉴얼 (4 페이지), 빠른 시작 매뉴얼 (5 페이지)

iHealth BP5 소유자 매뉴얼
result in measurement errors and a biocompatible hazard.
10.
This product might not meet its performance specifications if stored or used outside the
!
specified temperature and humidity ranges.
11.
Please do not share the cuff with any infectious person to avoid cross-infection.
!
12. This product should not be used as a USB device.
13. This product is verified by auscultatory method. It is recommended that you check Annex
B of ANSI/AAMI SP-10:2002+A1:2003+A2:2006 for verification method details if needed.
14. If the determined blood pressure (systolic or diastolic) is outside the rated range specified
in SPECIFICATIONS, the app will immediately display a technical alarm on screen. In
this case, consult a physician or ensure that proper measurement procedures are followed.
The technical alarm is preset in the factory and cannot be adjusted or inactivated. This
technical alarm is assigned as low priority according to IEC 60601-1-8.The technical alarm
is non-latching and does not need to be reset.
15. A medical AC adapter with an output of DC 5.0V and complies with IEC 60601-1/UL
60601-1 and IEC 60601-1-2/EN 60601-1-2 is suitable for this monitor, such as
ASP5-05010002JU (input: 100-240V, 50/60Hz, 200mA; output: DC 5V, 1.0A). Please note
that the monitor jack size is USB mini B.

BATTERY HANDLING AND USAGE

Do not change the battery. If the battery can no longer be charged, please contact Customer
!
Service.
• When charging is needed, please connect the monitor to a power source. The monitor can
work normally while charging.
• When the monitor is connected to an iPod touch, iPhone, or iPad, the battery volume will be
displayed on the iPod touch, iPhone, or iPad screen. If the power is less than 25%, please
11
the battery. The monitor will not work until the battery has enough power.
• When you charge the monitor, the LED will display with different colors indicating the charging
status. See the table below for details.
• It is suggested that you charge the battery when the battery is less than 25%. Overcharging the
battery may reduce its lifetime.
Lithium battery replacement by inadequately trained personnel could result in a hazard such as
!
a fire or explosion.
Do not plug or unplug the power cord into the electrical outlet with wet hands.
!
If the AC adapter is abnormal, please change the adapter.
!
Do not pull out the adapter when you are using the monitor.
!
Do not use any other type of AC adapter as it may harm the monitor.
!
The monitor, cable, battery and cuff must be disposed of according to local regulations at the
end of their usage.
Note: The battery has limited charge cycles and may eventually need to replaced by an iHealth
service provider. Battery life and charge cycles vary by use and settings.
Monitor Status
Status Indicator
Charging
Flashing green light
Fully charged
Steady green light
Low battery
Flashing red light (for a few seconds)
Abnormal state
Steady red light
12