DCB EtherPath SS-R1 문제 해결 - 페이지 2

{카테고리_이름} DCB EtherPath SS-R1에 대한 문제 해결을 온라인으로 검색하거나 PDF를 다운로드하세요. DCB EtherPath SS-R1 2 페이지. Troubleshooting the telnet server configuration
DCB EtherPath SS-R1에 대해서도 마찬가지입니다: 문제 해결 (2 페이지)

S: To verify the EtherPath configuration, check that:
● One EtherPath unit is configured as a Server and one as a Client: If both are Servers or both are
Clients, the link won't be established.
● A correct Remote Device IP Address value has been entered on the Client unit: This should be
the IP Address of the Server unit.
● The EtherPaths' LAN IP addresses are on the same subnet.
● The Port Configuration settings of the EtherPaths are matched to those of the PCs plugged
into them. If either of the PCs' serial port settings are different from the default settings of the
EtherPath (9600/8-N-1), the serial link will not work.
2