SECTION 2
5. Electric or Gas Boosted:
•
Electric Boosted - Confirm electrical connection is properly terminated by authorised personal
& switch on dedicated electrical circuit to ensure element circuit is operational. This can be
checked by monitoring the existing homes power meter. This process shall only be completed
after the tank is completely full of water and all air bled from the system. Failure to do so will
cause damage to the electric element and will not be covered under warranty.
•
Gas Boosted – Following manufacturers installation instructions located on the inside of the
front cover
7. Check all water outlets in the home to ensure water supply is present at all fixtures.
Overall System Dimensions
total space required
200
min distance from panels to edge of roof
A
Roof mounted Solar hot water (twin panel)
Installation Manual - Roof Mount Solar Hot Water - August 2017
2500
min distance
from panels to
2100
200
edge of roof
PANEL
1539
Roof Space
TANK
Hot Water Tank
Hot Water Panels
(Collectors)
1647
total space required
1247
PANEL
min distance
from tank to
200
1539
edge of roof
TANK
min distance from panels to edge of roof
Roof mounted solar hot water (single panel)
B
1300 829 118
min distance
from tank to
200
edge of roof
Roof Space
Hot Water Tank
Hot Water Panel
(Collectors)
i-heat.com.au