3. Install the pump to its place. Make sure that the drain line is above or at least at the
horizontal level with the axel. If the pump is installed drain line being under the
shaft it can damage the pump.
4. Install the pressure (P), drain (Dr), LS- (LS), and the suction (S) lines
5. Install the rest of the system and fill the system with oil.
6. After installing the rest of the system and filling it with oil run the system with idle
speed for 10 min at pressure being under 50 bar.
Bleeding/flushing the system is recommended before the full pressure range is
used.
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | [email protected] | www.dynaset.com
HYDRAULIC VARIABLE DISPLACEMENT PUMP
INSTALLATION GUIDE
9