d. Fasten the injector on the machine (see Fig. above).
3.3.2 Steps
11 Reverse Flushing
1) Connect black hose (outlet) to inlet port of the fuel distributor, and
then connect the actuation cable to the machine.
2) Press Left or Right arrow key to select Reverse Flushing.
3) Press RUN key (default test time is 1 minute).
4) Turn Pressure Adjusting Knob until the pressure is 0.25-0.3MPa.
5) When the working time is over, the machine will stop.
6) Release the fluid into the pump after test is completed.
Note:
1. Only up-inlet injector can fit Reverse Flushing.
2. Need not set up pulse width, system use default value.
3. Please make sure the test fluid is clean, so that the injector will not be
blocked.

3.4 Non-dismantle Cleaning(optional function)

To clean the whole fuel system of the engine, including fuel supply system,
burning room and the injector.
3.4.1 Preparation
1) Move the screw on the bottom of test fluid bottle, and release all test
fluid.
2) Open the cover of the engine chamber. Find out the fuel supply hose
and return hose of the fuel system.
3.4.2 Steps
.
- - 11 - -