PSXX-AR & PSXX-ARSC Manual
*Designed by Larry Maier
*Developed by DCC Specialties
*US Patent 7,810,435
New Timing Delay Features
New Programmable Power Up Status
New Auto Stop
For DCC Use Only
Versions Available:
PSXX-AR [Tortoise] & PSXX-ARSC [Kato, Peco, Atlas Snap Coils]
Compatible with PSXX and earlier PSX & PSX-AR units
Full Manual Available: tonystrains.com/psxx-manual
●
D12 Green LED On indicates DCC power J1 input
●
D11 & D20 Green LEDs On indicates DCC power J2 output
●
D23 Red LED On & D7 Green OFF indicates short circuit
●
D24 Blue LED indicates that current limiting is active. For marginal shorts, it may flash without
tripping the breaker. For hard shorts, it will light momentarily and then the breaker will trip.
1. All connections involve two wire inputs from the DCC Booster [or Main DCC Power Bus] into a PSXX-AR and two wire Outputs
to the isolated reversing section or loop.
2. All PSXX-AR Auto reverser/circuit breakers are ready to operate without programming.
3. PSXX-ARs are not compatible with Digitrax Analog Address [00] or any method that adjusts the "0" bit timing to allow operation
of an analog engine.
Test the PSXX-AR for functionality:
1.
Connect the PSXX-AR to a DCC power source and apply power.
a.
Verify D12 and D11 are illuminated.
2.
Use a short jumper wire to momentarily connect J1-1 to J2-1.
a.
Verify no change: D12 & D11 remain illuminated.
3.
Connect J1-1 to J2-2.
a.
Verify momentary flash of D24 [blue]; D12 & D20 are illuminated.
4.
Connect J1-1 to J2-1.
a.
Verify momentary flash of D24 [blue]; D12 & D11 are illuminated.
5.
Connect J1-2 to J2-1.
a.
Verify momentary flash of D24 [blue]; D12 & D20 are illuminated.
6.
Connect J1-2 to J2-2.
a.
Verify momentary flash of D24 [blue]; D12 & D11 are illuminated.
7.
Connect J2-1 to J2-2.
a.
Verify D12 and D23 [red] are illuminated.
b.
Verify D24 flashes on periodically about every 3-4 seconds.
c.
After the D24 short flash, verify D23 is steady on until the next D24 flash cycle.
•
If you are using both PSXX circuit breakers and PSXX-AR auto reversers on a layout, make sure the PSXX-AR J1
input is taking power from the J2 DCC track output of the PSXX
•
PSXX-AR Trip Rate Default = 1.8 amps
•
When PSXX are used with PSXX-AR, the PSXX-AR trip rate must be equal to or less than the trip rate of the PSXX.
•
PSXX default trip rate = 2amps
•
Reference PSXX-AR manual for setting trip rate.