Emerson Rosemount 648 빠른 설치 매뉴얼 - 페이지 12
{카테고리_이름} Emerson Rosemount 648에 대한 빠른 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Emerson Rosemount 648 18 페이지. Wireless dam monitor (wdm)
Emerson Rosemount 648에 대해서도 마찬가지입니다: 빠른 시작 매뉴얼 (14 페이지)
Rosemount 648 Wireless
Hazardous Locations Certificates
North American Certifications
Factory Mutual (FM) Approvals
I5 FM Intrinsically Safe, Non-incendive
Intrinsically Safe for Class I/II/III, Division 1, Groups A, B, C, D, E, F, and G.
Zone Marking: Class I, Zone 0, AEx ia llC
Temperature Codes T4 (T
Non-incendive for Class I, Division 2, Groups A, B, C, and D.
Dust Ignition-proof for Class II/III, Division 1, Groups E, F, and G.
Ambient temperature limits: -50 to 85 °C
Intrinsically Safe and Non-incendive when installed in accordance with Rosemount
drawing 00648-1000.
For use with Rosemount Power Module P/N 753-9220-0001 only.
Enclosure Type 4X/IP66/IP67
N5 FM Non-incendive and Dust Ignition-proof
Non-incendive for Class I, Division 2, Groups A, B, C, and D.
Dust Ignition-proof for Class II/III, Division 1, Groups E, F, and G.
Ambient temperature limits: -50 to 85 °C
For use with Rosemount Power Module P/N 753-9220-0001 only.
Enclosure Type 4X/IP66/IP67
Canadian Standards Association (CSA)
I6 CSA Intrinsically Safe
Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D.
Temp Code T3C
Enclosure Type 4X/IP66/IP67
For use with Rosemount Power Module P/N 753-9220-0001 only.
Intrinsically Safe when installed per Rosemount drawing 00648-1020.
12
= -50 to 70 °C)
amb
T5 (T
= -50 to 40 °C)
amb
Quick Installation Guide
00825-0100-4648, Rev CC
February 2012