Step Nine:
Release air using the purge-valve
TEST button and watch the pressure
gauge to see when the motors start.
The motors should start when the
pressure drops to approximately 80 PSI.
You may have to push the TEST button
several times before enough air is
released to lower the pressure to 80 PSI.
Step Ten:
Open the outlet valve on the tank to
pressurize the piping and wait until the
tank is fully pressurized and the motors
stop running.
Step Eleven:
Ensure that no equipment is drawing
pressure from the tank. When no equip-
ment is drawing on the tank, pressure
should drop no more than 1 PSI per
minute.
Watch the pressure gauge. If pressure
drops faster than 1 PSI per minute, an
air leak is indicated somewhere in the
system. Repair as necessary.
1 .8 00.6 24.2 79 3
C Series Installation Guide
Start-Up & Test