INSTALLATION
POSITION MODULES
Locate the Support Column in alignment with
1
the position for the 1/2" anchor bolts in the floor
template.
Push the Sink Module against the support column
2
and in the correct position over the stub-ups.
CONNECT MODULES AND LEVEL
Attach the Sink Module to the support column by
3
installing the 1/4-20 x 1-3/8" bolts into the
predrilled holes. Tighten bolts securely.
Push the Rear Storage Module against the back
4
of the Support Column.
Attach the Rear Storage Module to the support
5
column by installing the 1/4-20 x 1-3/8" bolts into
the predrilled holes. Tighten bolts securely.
Level the modules by placing a level on the
6
countertop and adjusting the height of the leveling
feet which are located at each corner of the modules.
Using a level, ensure that the support column is
7
plumb (perpendicular to level), both front to back
and side to side.
SERIES 4 & SERIES 5 CENTER ISLAND CABINET
Installation Instructions