recommend 30" distance from the bottom of the
hood to the cooktop surface.
The Dynasty Gas Cooktop must be installed in
accordance with the minimum clearances as
illustrated. Avoid placing cabinets directly above the
cooktop in order to reduce the hazards in reaching
over the appliance. When installed, the maximum
depth of the overhead cabinets is 13 inches. If the
cabinets are to be installed above a cooktop with a
charbroiler section, the bottom of the cabinets must
be protected with noncombustible materials. Note
that the minimum vertical distance between the
cooktop surface and the combustible cabinets above
the cooktop is 40". If a ventilating hood is used, we
Because of the high burner input rate of the Dynasty
Gas Cooktop, we strongly suggest that a professional
ventilating hood be installed above the appliance.
Please refer to the chart for the recommended
ventilating hood sizes.
><-.:;.
Recommended Size
ZERO CLEARANCE
Ventilating Hood
Model
DSCT-36-6
Vent Hood Size
600
CFM
y
'<
The hood width must be at least the same width as
the cooktop. The hood depth must be 19" minimum.
IMPORTANT: Any opening in the wall behind the
appliance and in the cabinet top under the appliance
must be sealed.